Abstract
Noninvasive diffusion magnetic resonance imaging (dMRI) has been widely employed in both clinical and research settings to investigate brain tissue microstructure. Despite the evidence that dMRI‐derived fractional anisotropy (FA) correlates with white matter properties, the metric is not specific. Recent studies have reported that FA is dependent on the b‐value, and its origin has primarily been attributed to either the influence of microstructure or the noise‐floor effect. A systematic investigation into the inter‐relationship of these two effects is however still lacking. This study aims to quantify contributions of the reported differences in intra‐ and extra‐neurite diffusivity to the observed changes in FA, in addition to the noise in measurements. We used in‐vivo and post‐mortem human brain imaging, as well as numerical simulations and histological validation, for this purpose. Our investigations reveal that the percentage difference of FA between b‐values (pdFA) has significant positive associations with neurite density index (NDI), which is derived from in‐vivo neurite orientation dispersion and density imaging (NODDI), or Bielschowsky's silver impregnation (BIEL) staining sections of fixed post‐mortem human brain samples. Furthermore, such an association is found to be varied with Signal‐to‐Noise Ratio (SNR) level, indicating a nonlinear interaction effect between tissue microstructure and noise. Finally, a multicompartment model simulation revealed that these findings can be driven by differing diffusivities of intra‐ and extra‐neurite compartments in tissue, with the noise‐floor further amplifying the effect. In conclusion, both the differences in intra‐ and extra‐neurite diffusivity and noise‐floor effects significantly contribute to the FA difference associated with the b‐value.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (2021FZZX002‐19)
- Major Scientific Project of Zhejiang Laboratory (2020ND8AD01)
- National Natural Science Foundation of China (81871428)
This publication has 79 references indexed in Scilit:
- Effect of B-value in revealing postinfarct myocardial microstructural remodeling using MR diffusion tensor imagingMagnetic Resonance Imaging, 2013
- A comprehensive reliability assessment of quantitative diffusion tensor tractographyNeuroImage, 2012
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Axon diameter mapping in the presence of orientation dispersion with diffusion MRINeuroImage, 2011
- MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high fieldNeuroImage, 2010
- Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissueMagnetic Resonance in Medicine, 2009
- Diffusion Tensor MR Imaging and Fiber Tractography: Technical ConsiderationsAmerican Journal of Neuroradiology, 2008
- Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5TJournal of Magnetic Resonance Imaging, 2007
- An approach to high resolution diffusion tensor imaging in fixed primate brainNeuroImage, 2007
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005