Validation of pitchAI TM markerless motion capture using marker-based 3D motion capture
- 21 November 2022
- journal article
- research article
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 24 (3) , 587-607
Abstract
This study sought to compare and validate baseball pitching mechanics, including joint angles and spatiotemporal parameters, from a single camera markerless motion capture solution with a 3D optical marker-based system. Ten healthy pitchers threw 2–3 maximum effort fastballs while concurrently using marker-based optical capture and pitchAITM (markerless) motion capture. Time-series measures were compared using R-squared (r2), and root mean square error (RMSE). Discrete kinematic measures at foot plant, maximal shoulder external rotation, and ball release, plus four spatiotemporal parameters were evaluated using descriptive statistics, Bland-Altman analyses, Pearson’s correlation coefficients, p-values, r2, and RMSE. For time-series angles, r2 ranged from 0.69 (glove arm shoulder external rotation) to 0.98 (trunk and pelvis rotation), and RMSE ranged from 4.37° (trunk lateral tilt) to 20.78° (glove arm shoulder external rotation). Bias for individual joint angle and spatiotemporal parameters ranged from −11.31 (glove arm shoulder horizontal abduction; MER) to 12.01 (ball visible). RMSE was 3.62 m/s for arm speed, 5.75% height for stride length and 21.75 ms for the ball visible metric. pitchAITM can be recommended as a markerless alternative to marker-based motion capture for quantifying pitching kinematics. A database of pitchAITM ranges should be established for comparison between systems.Keywords
All Related Versions
Funding Information
- Canada Research Chairs
This publication has 35 references indexed in Scilit:
- Human3.6M: Large Scale Datasets and Predictive Methods for 3D Human Sensing in Natural EnvironmentsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2013
- The Kinetic Chain in Overhand Pitching: Its Potential Role for Performance Enhancement and Injury PreventionSports Health: A Multidisciplinary Approach, 2010
- Variability in baseball pitching biomechanics among various levels of competitionSports Biomechanics, 2009
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- BaseballSports Biomechanics, 2003
- ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spineJournal of Biomechanics, 2002
- The position of the rotation center of the glenohumeral jointJournal of Biomechanics, 2000
- The measurement of human motion: A comparison of commercially available systemsHuman Movement Science, 1999
- Biomechanics of the Elbow During Baseball PitchingJournal of Orthopaedic & Sports Physical Therapy, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986