Fat-water separation using a region-growing algorithm with self-feeding phasor estimation
Authors:
- 14 June 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (6) , 2390-2401
Abstract
Purpose To develop a novel region-growing algorithm with self-feeding phasor estimation for robust fat-water separation. Theory and Methods The proposed seed pixel identification and region-growing methods were performed independently at different resolutions. Multiple phasor maps were obtained at lower resolutions and then merged into a new seed map, which was used to generate the final phasor map at the finest resolution. The final fat and water images were reconstructed based on this phasor map. The proposed method was compared with traditional region-growing methods, multiresolution methods, and graph-cut methods using data from the ISMRM 2012 Challenge. All methods were scored on a scale of 0 to 10000. Results The average score of all 17 data sets from the ISMRM 2012 Challenge was 9928, with 13 of the 17 scores surpassing 9900. The lowest score was 9697 from data set #12; there was no apparent fat-water swap observed throughout these data sets. Conclusions The self-feeding mechanism of phasor estimation ensures the reliability of seed pixel selection at the finest resolution. Compared with traditional multiple resolution methods and region-growing methods, the proposed method is shown to be more robust when applied to disjoint areas and to regions with strong field inhomogeneity. Magn Reson Med 77:2390–2401, 2016. © 2016 International Society for Magnetic Resonance in MedicineKeywords
Funding Information
- National Natural Science Foundation of China (81327801, 81527901, 61302040, 81301242, 11504401, U1301258)
- Shenzhen Science and Technology Research Program (JCYJ20150630114942317, JCYJ20150521094519487)
This publication has 22 references indexed in Scilit:
- Value of MRI and MRS fat measurements to complement conventional screening methods for childhood obesityJournal of Magnetic Resonance Imaging, 2015
- T1 independent, T2* corrected chemical shift based fat–water separation with multi‐peak fat spectral modeling is an accurate and precise measure of hepatic steatosisJournal of Magnetic Resonance Imaging, 2011
- Comparison of Fat–Water MRI and Single‐voxel MRS in the Assessment of Hepatic and Pancreatic Fat Fractions in HumansObesity, 2010
- Phase‐Modulated binomial RF pulses for fast spectrally‐selective musculoskeletal imagingMagnetic Resonance in Medicine, 1996
- MR imaging of the breast with rotating delivery of excitation off resonance: clinical experience with pathologic correlation.Radiology, 1993
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Multisection fat-water imaging with chemical shift selective presaturation.Radiology, 1987
- MR ImagingJournal of Computer Assisted Tomography, 1985
- 1H NMR chemical shift selective (CHESS) imagingPhysics in Medicine & Biology, 1985
- Simple proton spectroscopic imaging.Radiology, 1984