Long-term outcome of cementless total hip arthroplasty with threaded Tropic® acetabular cup and Corail® femoral stem
Authors:
- Fernando AlmeidaFAFernando Almeida
- Silvia GállegoSGSilvia Gállego
- Francisco ArgüellesFAFrancisco Argüelles
- Antonio SilvestreASAntonio Silvestre
- 30 September 2021
- journal article
- research article
- Published by Universa BV in Acta Orthopaedica Belgica
- Vol. 87 (3) , 393-399
Abstract
This study investigates the clinical and radiological results of a tapered femoral stem (Corail®) and uncemented threaded acetabular cups (Tropic®) and in addition an analysis of the complications and retrieved implants was conducted. Between January 1990 and September 1998, 301 total hips arthroplasties in 268 patients were implanted. 78 patients (87 hips) had died and 9 patients (12 hips) had been lost to follow-up, leaving at the time of the latest follow-up 180 patients (202 hips). The mean age at surgery was 56,1 (27-75) years. Of the 154 unrevised hips, the median Harris and Merle d´Aubigne and Postel hip scores were 83,3 points and 15,3 points respectively at the latest follow-up. The median follow-up time was 16.9 years (10,4-25). No femoral component was revised for aseptic loosening ; osteolysis was observed in the 9,5% of the implants (13 stems). 48 hips (23%) were revised and 27 cups (56,2%) needed revision surgery because of massive polyethylene wear. Pelvic osteolysis was found out in 80 cups (58,8%). 87 hips (63,9%) showed signs of a progressive wear of the liner, more than 2mm in 48 hips. Kaplan-Meier survivorship analysis at 15 years follow-up was 81.2% with revision for any reason (85.8% for mechanical or radiographic loosening). High rates of polyethylene wear and the high prevalence of pelvic osteolysis are serious matters in these types of implants with high rates of revision at 15 years follow-up so we decided to abandon the concept of a threaded cup design in favor of a press-fit acetabular cup.Keywords
This publication has 27 references indexed in Scilit:
- High 10-Year Survival Rate with an Anatomic Cementless Stem (SPS)Clinical Orthopaedics and Related Research, 2012
- Second-generation Annealed Highly Cross-linked Polyethylene Exhibits Low WearClinical Orthopaedics and Related Research, 2012
- Long-term results of the threaded Mecron cup in primary total hip arthroplastyInternational Orthopaedics, 2009
- Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: Follow-up of 75 hips for 15–18 yearsActa Orthopaedica, 2008
- Hydroxyapatite-Coated Tapered Cementless Femoral Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2007
- Cementless Lord total hip arthroplasty: Cup loosening common after minimum 10-year follow-up of 103 hipsActa Orthopaedica, 2001
- Survivorship of rough-surfaced threaded acetabular cups 382: Consecutive primary Zweymiiller cups followed for 0.2–12 yearsActa Orthopaedica, 1998
- Hydroxyapatite Coated ImplantsClinical Orthopaedics and Related Research, 1997
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958