Abstract
Patients with immune heparin‐induced thrombocytopenia (HIT) possess antibodies that bind to a complex of platelet factor 4 (PF4) and heparin. We observed that HIT antibodies will also bind to PF4 alone adsorbed on polystyrene ELISA wells but not to soluble PF4 in the absence of heparin. Having developed a technique to affinity‐purify anti‐PF4‐heparin HIT IgG, we are able to provide the first estimates of the avidity of HIT IgG. HIT IgG displayed relatively high functional affinity for both PF4‐heparin (Kd = 7–30 nm) and polystyrene adsorbed PF4 alone (Kd = 20–70 nm). Furthermore, agarose beads coated with PF4 alone were almost as effective as beads coated with PF4 plus heparin in depleting HIT plasmas of anti‐PF4‐heparin antibodies. We conclude that the HIT antibodies which bind to polystyrene adsorbed PF4 without heparin are largely the same IgG molecules that bind PF4‐heparin and therefore most HIT antibodies bind epitope(s) on PF4 and not epitope(s) formed by part of a PF4 molecule and part of a heparin molecule. Binding of PF4 to heparin (optimal) or polystyrene/agarose (suboptimal) promotes recognition of this epitope.

This publication has 20 references indexed in Scilit: