Red blood cell (RBC) volume can be independently determined in vivo in humans using RBCs labeled at different densities of biotin
- 10 January 2011
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 51 (1) , 148-157
Abstract
BACKGROUND: Anemia is a serious problem in critically ill neonates. To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin therapy, repeated measurement of red blood cell volume (RCV) and blood volume is useful. To extend our previous sheep study in which RBCs were labeled at four different biotin densities, we assessed the validity of this multidensity method for in vivo measurement of circulating RCV in humans. STUDY DESIGN AND METHODS: In eight healthy adults, autologous RBCs were biotinylated at each of four biotin densities (6, 18, 54, and 162 µg biotinylation reagent/mL RBC), mixed, and infused intravenously; blood was sampled at 10, 20, and 60 minutes. At each time, RCV was calculated from dilution of individual RBC populations enumerated by flow cytometry. RCV measurements from the population of RBCs biotinylated at 6 µg/mL were chosen as the reference values because this density had been previously validated against the 51Cr method in vitro and in vivo in humans. RESULTS: Values for RCVs were not significantly different among the four densities of biotinylated RBCs at any of the three time points and did not change over 60 minutes. CONCLUSIONS: These studies provide evidence that four densities of biotinylated RBCs can be used in vivo for simultaneous, independent, accurate measurements of RCV in humans. We speculate that this method will also be useful for repeated measurement of RCV and blood volume in infants and other patient populations in whom radioactive labels should be avoided.Keywords
This publication has 28 references indexed in Scilit:
- Red blood cell (RBC) volume can be independently determined in vivo in the sheep using ovine RBCs labeled at different densities of biotinTransfusion, 2010
- Red blood cell volume can be independently determined in vitro using sheep and human red blood cells labeled at different densities of biotinTransfusion, 2009
- Red Cell Volume Can Be Accurately Determined in Sheep Using a Nonradioactive Biotin LabelPediatric Research, 2008
- A randomized clinical trial comparing immediate versus delayed clamping of the umbilical cord in preterm infants: short‐term clinical and laboratory endpointsTransfusion, 2008
- Conducting ethical research in pediatrics: A brief historical overview and review of pediatric regulationsThe Journal of Pediatrics, 2006
- Determination of red cell volume in infants needing blood transfusionTransfusion Medicine, 2000
- Red cell volume and cardiac output in anaemic preterm infants.Archives of Disease in Childhood, 1990
- Red cell volume measurements and acute blood loss in high-risk newborn infantsThe Journal of Pediatrics, 1977
- Deduction of Mean Red‐Cell Life‐Span from 51Cr Survival Curves*British Journal of Haematology, 1971
- THE USE OF RADIOACTIVE CHROMIUM 51 AS AN ERYTHROCYTE TAGGING AGENT FOR THE DETERMINATION OF RED CELL SURVIVAL IN VIVO 12Journal of Clinical Investigation, 1953