Simultaneous electrophoretic analysis of proteins of very high and low molecular mass using Tris‐acetate polyacrylamide gels
- 20 April 2010
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 31 (8) , 1318-1321
Abstract
To separate and analyze giant and small proteins in the same electrophoresis gel, we have used a 3–15% polyacrylamide gradient gel containing 2.6% of the crosslinker bisacrylamide and 0.2 M of Tris‐acetate buffer (pH 7.0). Samples were prepared in a sample buffer containing lithium dodecyl sulphate and were run in the gel described above using Tris‐Tricine‐SDS‐sodium bisulfite buffer, pH 8.2, as electrophoresis buffer. Here, we show that this system can be successfully used for general applications of SDS‐PAGE such as CBB staining and immunoblot. Thus, by using Tris‐acetate 3–15% polyacrylamide gels, it is possible to simultaneously analyze proteins, in the mass range of 10–500 kDa, such as HERC1 (532 kDa), HERC2 (528 kDa), mTOR (289 kDa), Clathrin heavy chain (192 kDa), RSK (90 kDa), S6K (70 kDa), β‐actin (42 kDa), Ran (24 kDa) and LC3 (18 kDa). This system is highly sensitive since it allows detection from as low as 10 μg of total protein per lane. Moreover, it has a good resolution, low cost, high reproducibility and allows for analysis of proteins in a wide range of weights within a short period of time. All these features together with the use of a standard electrophoresis apparatus make the Tris‐acetate‐PAGE system a very helpful tool for protein analysis.Keywords
This publication has 7 references indexed in Scilit:
- Simultaneous electrophoretic analysis of proteins of very high and low molecular weights using low‐percentage acrylamide gel and a gradient SDS‐PAGE gelElectrophoresis, 2006
- Tricine–SDS-PAGENature Protocols, 2006
- Models of protein modification in Tris–glycine and neutral pH Bis–Tris gels during electrophoresis: Effect of gel pHAnalytical Biochemistry, 2005
- SDS polyacrylamide gel electrophoresisTrends in Biochemical Sciences, 2000
- Effect of Incubation of Solutions of Proteins Containing Dodecyl Sulfate on the Cleavage of Peptide Bonds by BoilingAnalytical Biochemistry, 1995
- A new multiphasic buffer system for sodium dodecyl sulfate‐polyacrylamide gel electrophoresis of proteins and peptides with molecular masses 100 000–1000, and their detection with picomolar sensitivityElectrophoresis, 1991
- Tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis for the separation of proteins in the range from 1 to 100 kDaAnalytical Biochemistry, 1987