Abstract
Background: Single-photon emission computed tomography (SPECT) can cause an over- or underestimation of tissue activity concentration due to limitations in spatial resolution compared to the structures under study. This is commonly referred to as partial volume effect (PVE). Ideally, the PVE should be controlled for and corrected. One such correction method involves determining recovery coefficients (RC) from phantom measurements. In the literature, several studies applying simplified geometries are available. In this study, we aimed to determine kidney PVE for realistic kidney geometries. Furthermore, we proposed a new surrogate metric for predicting the extent of PVE in kidneys. Material and methods: Based on patients’ CT data, we manufactured fillable phantoms using a 3D-printer. Nine cortex-only and ten whole-parenchyma phantoms were obtained, and one ellipsoidal phantom for comparison. To measure PVE, we placed the phantoms in a torso phantom and filled them with a specified activity concentration. The phantoms’ RCs were determined from fully quantitative SPECT/CT acquisitions at three different target-to-background ratios (TBRs). Additionally, the surface area-to-volume (SA:V) ratio was determined for all phantoms and correlated with RCs. Results: For SPECT reconstructions with 36 iterations, average RC ± one standard deviation at a 10-to-1 TBR was 76.3 ± 1.5% and 48.4 ± 8.3% for whole-parenchyma and cortex-only phantoms, respectively. The RC for the ellipsoidal phantom was 85.4%. The RC for whole-parenchyma was significantly higher than for cortex-only phantoms (p < 0.01). The RC variance was significantly higher for cortex-only phantoms (p < 0.01). A highly significant correlation of the SA:V ratio and RC was found for all phantoms. (R2 of linear regression was between 0.96 and 0.98.) Conclusion: Changes in the specific shape of the kidneys cause large changes in PVE magnitude. Therefore, RCs derived from more simple phantoms are most likely insufficient to correct the PVE in patient images. Furthermore, one should account for the fact that intra-renal activity distribution significantly influences the extent of PVE. Additionally, we found that the SA:V ratio excellently models kidney RCs; potentially, this approach could also be applied to other geometries and represents an alternative to full imaging process simulations to determine the extent of PVE.Keywords
Funding Information
- Universitätsklinikum Erlangen
This publication has 15 references indexed in Scilit:
- MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT Applied for Dosimetry of Radiopharmaceutical TherapyJournal of Nuclear Medicine, 2015
- Quantitative SPECT/CT Imaging of 177Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide TherapyMolecular Imaging and Biology, 2014
- Influence of cold walls on PET image quantification and volume segmentation: A phantom studyMedical Physics, 2013
- MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide TherapyJournal of Nuclear Medicine, 2012
- Absolute quantification in SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT systemCancer Imaging, 2011
- Quantitative Accuracy of Clinical 99mTc SPECT/CT Using Ordered-Subset Expectation Maximization with 3-Dimensional Resolution Recovery, Attenuation, and Scatter CorrectionJournal of Nuclear Medicine, 2010
- Absorbed fractions in ellipsoidal volumes for β−radionuclides employed in internal radiotherapyPhysics in Medicine & Biology, 2009
- A recovery coefficient method for partial volume correction of PET imagesAnnals of Nuclear Medicine, 2009
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006