Robust Deadbeat Control Scheme for a Hybrid APF With Resetting Filter and ADALINE-Based Harmonic Estimation Algorithm
Authors:
- 18 November 2010
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 58 (9) , 3893-3904
Abstract
A novel hybrid active power filter (HAPF) topology is proposed, which shows advantages of the conventional HAPF and the LCL filter in terms of reduced dc-link voltage, lower switching ripples, and less electromagnetic interference injection. To enhance the noise rejection capability of the digital controller, the resetting filters (RFs) are utilized as prefilters before the analog/digital sampling stage. A robust deadbeat current control law is derived based on the average current tracking scheme, where the effect of the RFs is favorably incorporated. To alleviate the difficulties in current controller design, the ac-side capacitor voltage of the HAPF is estimated by using the adaptive linear neural network identifier in the load current feedforward loop. Hence, a simple proportional controller is utilized in the inner current loop. Moreover, the grid current feedback and load current feedforward strategies are used to achieve precise current tracking and fast dynamic response. A 75-kVA prototype system is built for verification. The validity of the proposed HAPF and its control algorithms are confirmed by the experimental results.Keywords
This publication has 28 references indexed in Scilit:
- Performance Improvement of LCL-Filter-Based Grid-Connected Inverters Using PQR Power TransformationIEEE Transactions on Power Electronics, 2009
- A Space-Vector Discrete Fourier Transform for Unbalanced and Distorted Three-Phase SignalsIEEE Transactions on Industrial Electronics, 2009
- Selective Harmonic-Compensation Control for Single-Phase Active Power Filter With High Harmonic RejectionIEEE Transactions on Industrial Electronics, 2009
- Multifunctional VSC Based on a Novel Fortescue Reference Signal GeneratorIEEE Transactions on Industrial Electronics, 2009
- A Two-Stage ADALINE for Harmonics and Interharmonics MeasurementIEEE Transactions on Industrial Electronics, 2009
- Instantaneous Reactive Power Theory: A Reference in the Nonlinear Loads CompensationIEEE Transactions on Industrial Electronics, 2009
- A New Control Technique for Three-Phase Shunt Hybrid Power FilterIEEE Transactions on Industrial Electronics, 2009
- Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental ResultsIEEE Transactions on Industrial Electronics, 2008
- On setting the DC voltage level of an active power filterInternational Journal of Circuit Theory and Applications, 2007
- A closed-loop selective harmonic compensation for active filtersIEEE Transactions on Industry Applications, 2001