Abdominal Applications of 3.0-T MR Imaging: Comparative Review versus a 1.5-T System
Authors:
- Jin-Young ChoiJCJin-Young Choi
- Myeong-Jin KimMKMyeong-Jin Kim
- Yong Eun ChungYCYong Eun Chung
- Ji Youn KimJKJi Youn Kim
- Alun C JonesAJAlun C Jones
- Jan de BeckerJBJan de Becker
- Marc van CauterenMCMarc van Cauteren
- 1 July 2008
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 28 (4) , e30
Abstract
With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.Keywords
This publication has 18 references indexed in Scilit:
- Body MR Imaging at 3.0 T: Understanding the Opportunities and ChallengesRadioGraphics, 2007
- Abdominal MR Imaging at 3TMagnetic Resonance Imaging Clinics of North America, 2006
- Brain Tumor Enhancement in Magnetic Resonance ImagingInvestigative Radiology, 2005
- Abdominal Magnetic Resonance Imaging at 3.0 TTopics in Magnetic Resonance Imaging, 2005
- Approach to Abdominal Imaging at 1.5 Tesla and Optimization at 3 TeslaMagnetic Resonance Imaging Clinics of North America, 2005
- Parallel Imaging at High Field StrengthTopics in Magnetic Resonance Imaging, 2004
- High field body MR imaging: Preliminary experiencesClinical Imaging, 2004
- Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 TeslaMagnetic Resonance in Medicine, 2003
- High field human imagingJournal of Magnetic Resonance Imaging, 2003
- Abdominal imaging at 4 T MR system: a preliminary resultEuropean Journal of Radiology, 2003