Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
- 26 February 2010
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 28 (2) , 110-116
Abstract
High-energy photons are most commonly used in radiotherapy to treat cancer. Wedge filters are required to obtain homogeneous dose distribution in the patient. Different wedge filter types create different surface doses. In this study, the effect of the virtual and physical wedge filters on the surface and build-up region doses was examined for 6- and 18-MV high-energy photon beams. The measurements were made in a water equivalent phantom in the build-up region at a 100-cm source-to-surface distance for various field sizes using virtual and physical wedge filters having different angles. A parallel-plate ion chamber was used to measure the percent depth doses. The percentage dose at the surface increased as the field size increased for open, virtual, and physical wedged beams. For open, physical, and virtual wedged beams, the surface doses were found to be 15.4%, 9.9%, and 15.9% with 6-MV photons and 10.6%, 8.8%, 11.9% with 18-MV photons, respectively, at 10 × 10 cm2 field size. Build-up doses of virtual wedged beams were similar to those of open beams. Surface and buildup doses of physical wedged beams were lower than those of open and virtual wedged beams.Keywords
This publication has 22 references indexed in Scilit:
- Optimal clinical implementation of the siemens virtual wedgeMedical Dosimetry, 2003
- Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear acceleratorJournal of Applied Clinical Medical Physics, 2003
- The Siemens Virtual WedgeMedical Dosimetry, 1997
- Surface and peripheral doses of dynamic and physical wedgesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997
- Effects of beam modifiers and immobilization devices on the dose in the build-up regionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994
- Entrance and exit dose regions for a clinac-2100cInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Evaluation of a diode detector array for measurement of dynamic wedge dose distributionsMedical Physics, 1993
- Dosimetric characteristics of wedges mounted beyond the blocking trayMedical Physics, 1992
- The effect of a dynamic wedge in the medial tangential field upon the contralateral breast doseInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990
- Electron contamination from different materials in high energy photon beamsPhysics in Medicine & Biology, 1985