Improvement of a mine fire simulation program — incorporation of smoke rollback into MFIRE 3.0
Authors:
- 12 September 2011
- journal article
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 30 (1) , 29-39
Abstract
Smoke rollback is a dangerous threat to miners and firefighters in an underground mine fire. The ability to predict smoke rollback can greatly improve the chances for safe miner evacuation and mine fire control and firefighting. A modified semi-empirical equation based on large-scale experiments conducted by the National Institute for Occupational Safety and Health (NIOSH) was developed to quantify smoke rollback during an underground mine fire. The equation was incorporated into a mine fire simulation program (MFIRE 3.0) to allow the user to predict the occurrence of smoke rollback and calculate the smoke rollback distance. This article describes the development of the equation and compares the experimental results with those predicted by MFIRE 3.0. The results indicate that the improved MFIRE 3.0 is capable of determining smoke rollback in a fire entry, not only to provide early warning for smoke rollback but also to verify the effectiveness of smoke rollback control efforts.Keywords
This publication has 4 references indexed in Scilit:
- Control of smoke flow in tunnel fires using longitudinal ventilation systems – a study of the critical velocityFire Safety Journal, 2000
- On smoke control for tunnels by longitudinal ventilationTunnelling and Underground Space Technology, 1998
- Smoke control in sloping tunnelsFire Safety Journal, 1996
- Control of smoke flow in tunnel firesFire Safety Journal, 1995