Unrestrained Acoustic Plethysmograph for Measuring Tidal Volume in Mice
- 1 August 2006
- journal article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (9) , 1494-1499
Abstract
The traditional method for measurement of tidal volume in unrestrained mice relies on pressure changes induced by a freely respiring animal in a whole body plethysmograph. These changes have been assumed to be the result of thermo-hygrometric differences between respired air and gas within the chamber. It is known, however, that gas compression in the lung can also contribute significantly to changes in plethysmograph pressure. This study describes an acoustic plethysmograph for mice that is capable of measuring the tidal volume time series without the errors associated with the traditional method. The plethysmograph was designed as a resonating cavity at a fixed frequency. It had a sharp resonant peak and was tuned so that changes in body volume produced nearly linear changes in sound amplitude. The plethysmograph was tested with a water filled balloon connected to a syringe pump. The volume of the balloon was varied as a triangle wave with an amplitude of 250 μL. The RMS error between measured and delivered volume was 4.43 μL. A volume step test, performed to assess the response time of the system, showed that the plethysmograph responded in less than one millisecond.Keywords
This publication has 14 references indexed in Scilit:
- A reevaluation of the validity of unrestrained plethysmography in miceJournal of Applied Physiology, 2002
- Whole-body plethysmography, does it measure tidal volume of small animals?Canadian Journal of Physiology and Pharmacology, 1998
- Noninvasive Measurement of Airway Responsiveness in Allergic Mice Using Barometric PlethysmographyAmerican Journal of Respiratory and Critical Care Medicine, 1997
- Pre-term infant volume measurements by acoustic plethysmographyJournal of Biomedical Engineering, 1993
- Comparative psychoacousticsHearing Research, 1988
- Body Volume and Fat-Free Mass Determinations by Acoustic PlethysmographyPediatric Research, 1988
- An Acoustic Plethysmograph to Measure Total Infant Body VolumeJournal of Biomechanical Engineering, 1985
- Use of a resonating cavity to measure body volumeThe Journal of the Acoustical Society of America, 1985
- SOUND AND ITS SIGNIFICANCE FOR LABORATORY ANIMALSBiological Reviews, 1982
- A theoretical analysis of the barometric method for measurement of tidal volumeRespiration Physiology, 1978