Silver Oxide Nanowalls Grown on Cu Substrate as an Enzymeless Glucose Sensor
- 25 November 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (12) , 2829-2834
Abstract
Ag2O nanowalls consisting of densely packed nanoplates based on a Cu substrate were synthesized through a facile one-pot hydrothermal method. A new enzymeless glucose sensor of Cu−Ag2O nanowalls was fabricated. The Cu−Ag2O nanowalls showed higher catalysis on glucose oxidation than traditional Ag2O nanoflowers and Cu−Ag2O nanospindles. At an applied potential of 0.4 V, the sensor produced an ultrahigh sensitivity to glucose (GO) of 298.2 μA mM−1. Linear response was obtained over a concentration range from 0.2 mM to 3.2 mM with a detection limit of 0.01 mM (S/N = 3). Satisfyingly, the Cu−Ag2O nanowalls modified electrode was not only successfully employed to eliminate the interferences from uric acid (UA) acid ascorbic (AA) and also fructose (FO) during the catalytic oxidation of glucose. The Cu−Ag2O nanowalls modified electrode allows highly sensitive, excellently selective, stable, and fast amperometric sensing of glucose and thus is promising for the future development of nonenzymatic glucose sensors.Keywords
This publication has 28 references indexed in Scilit:
- Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrodeBiosensors and Bioelectronics, 2009
- Pt–Pb nanowire array electrode for enzyme-free glucose detectionBiosensors and Bioelectronics, 2008
- Preparation of functionalized copper nanoparticles and fabrication of a glucose sensorSensors and Actuators B: Chemical, 2006
- Formation of Uniform CuO Nanorods by Spontaneous Aggregation: Selective Synthesis of CuO, Cu2O, and Cu Nanoparticles by a Solid−Liquid Phase Arc Discharge ProcessThe Journal of Physical Chemistry B, 2005
- Biosensors for real-time in vivo measurementsBiosensors and Bioelectronics, 2005
- An integrated bienzyme glucose oxidase–fructose dehydrogenase–tetrathiafulvalene-3-mercaptopropionic acid–gold electrode for the simultaneous determination of glucose and fructoseBioelectrochemistry, 2004
- Electrochemical detection of carbohydrates at carbon-nanotube modified glassy-carbon electrodesElectrochemistry Communications, 2004
- Quadruple-pulsed amperometric detection for simultaneous flow injection determination of glucose and fructoseAnalytica Chimica Acta, 2001
- Determination of glucose and fructose in mixtures by a kinetic method with chemiluminescence detectionAnalytica Chimica Acta, 1999
- A Tri-Enzyme Electrode Probe for the Sequential Determination of Fructose and Glucose in the Same SampleAnalytical Letters, 1997