Efficient approximation of cardiac mechanics through reduced‐order modeling with deep learning‐based operator approximation
Open Access
- 3 November 2023
- journal article
- research article
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (1) , e3783
Abstract
Reducing the computational time required by high‐fidelity, full‐order models (FOMs) for the solution of problems in cardiac mechanics is crucial to allow the translation of patient‐specific simulations into clinical practice. Indeed, while FOMs, such as those based on the finite element method, provide valuable information on the cardiac mechanical function, accurate numerical results can be obtained at the price of very fine spatio‐temporal discretizations. As a matter of fact, simulating even just a few heartbeats can require up to hours of wall time on high‐performance computing architectures. In addition, cardiac models usually depend on a set of input parameters that are calibrated in order to explore multiple virtual scenarios. To compute reliable solutions at a greatly reduced computational cost, we rely on a reduced basis method empowered with a new deep learning‐based operator approximation, which we refer to as Deep‐HyROMnet technique. Our strategy combines a projection‐based POD‐Galerkin method with deep neural networks for the approximation of (reduced) nonlinear operators, overcoming the typical computational bottleneck associated with standard hyper‐reduction techniques employed in reduced‐order models (ROMs) for nonlinear parametrized systems. This method can provide extremely accurate approximations to parametrized cardiac mechanics problems, such as in the case of the complete cardiac cycle in a patient‐specific left ventricle geometry. In this respect, a 3D model for tissue mechanics is coupled with a 0D model for external blood circulation; active force generation is provided through an adjustable parameter‐dependent surrogate model as input to the tissue 3D model. The proposed strategy is shown to outperform classical projection‐based ROMs, in terms of orders of magnitude of computational speed‐up, and to return accurate pressure‐volume loops in both physiological and pathological cases. Finally, an application to a forward uncertainty quantification analysis, unaffordable if relying on a FOM, is considered, involving output quantities of interest such as, for example, the ejection fraction or the maximal rate of change in pressure in the left ventricle.Keywords
All Related Versions
This publication has 76 references indexed in Scilit:
- Computational Medicine: Translating Models to Clinical CareScience Translational Medicine, 2012
- A Novel Rule-Based Algorithm for Assigning Myocardial Fiber Orientation to Computational Heart ModelsAnnals of Biomedical Engineering, 2012
- Active Stress vs. Active Strain in Mechanobiology: Constitutive IssuesJournal of Elasticity, 2011
- Whole-Heart ModelingCirculation Research, 2011
- Coupling multi-physics models to cardiac mechanicsProgress in Biophysics and Molecular Biology, 2011
- A general multipurpose interpolation procedure: the magic pointsCommunications on Pure and Applied Analysis, 2009
- Coupling of a 3D Finite Element Model of Cardiac Ventricular Mechanics to Lumped Systems Models of the Systemic and Pulmonic CirculationAnnals of Biomedical Engineering, 2006
- Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchersAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Numerical solution of saddle point problemsActa Numerica, 2005
- Finite element stress analysis of left ventricular mechanics in the beating dog heartJournal of Biomechanics, 1995