Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
Open Access
- 7 January 2021
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (1) , e0245144
Abstract
Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool. Here, loop-mediated isothermal amplification (LAMP) in combination with a lateral-flow biosensor (LFB) was developed for visual inspection of C. perfringens-specific cpa gene. The specificity of the developed test was evaluated against 40 C. perfringens and 35 other bacterial strains, which showed no cross-reactivity, indicating 100% inclusivity and exclusivity. LAMP-LFB detection limit for artificially contaminated samples after enrichment for 16 h was 1–10 CFU/g sample, which was comparable to the commercial real-time PCR kit. The detection performance of LAMP-LFB was also compared to culture-based method using 95 food samples, which revealed the sensitivity (SE), specificity (SP) and Cohen's kappa coefficient (κ) of 88.0% (95% CI, 75.6%-95.4%), 95.5% (95% CI, 84.8%-99.4%) and 0.832 (95% CI, 0.721–0.943), respectively. Area under the receiver operating characteristic (ROC) curve was 0.918 (95% CI, 0.854–0.981), indicating LAMP-LFB as high relative accuracy test. In conclusion, LAMP-LFB assay is a low-cost qualitative method and easily available for routine detection of C. perfringens in food samples, which could serve as an alternative to commercial test kit.Keywords
Funding Information
- International Research Network (IRN) under The Thailand Research Fund (Grant numbers IRN59W0007)
- International Research Network (IRN) under The Thailand Research Fund (Grant numbers IRN59W0007)
- International Research Network (IRN) under The Thailand Research Fund (Grant numbers IRN59W0007)
- International Research Network (IRN) under The Thailand Research Fund (Grant numbers IRN59W0007)
- International Research Network (IRN) under The Thailand Research Fund (Grant numbers IRN59W0007)
This publication has 27 references indexed in Scilit:
- The Development and Evaluation of a Loop-Mediated Isothermal Amplification Method for the Rapid Detection of Salmonella enterica serovar TyphiPLOS ONE, 2015
- Comparison of Conventional PCR, Multiplex PCR, and Loop-Mediated Isothermal Amplification Assays for Rapid Detection of Arcobacter SpeciesJournal of Clinical Microbiology, 2014
- Evaluation of Multiplex PCR with Enhanced Spore Germination for Detection ofClostridium difficilefrom Stool Samples of the Hospitalized PatientsBioMed Research International, 2013
- Detection of Enterotoxigenic Clostridium perfringens in Meat Samples by Using Molecular MethodsApplied and Environmental Microbiology, 2011
- Rapid and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to rpoS geneMolecular and Cellular Probes, 2011
- Novel insights into the epidemiology of Clostridium perfringens type A food poisoningFood Microbiology, 2011
- The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticusLetters in Applied Microbiology, 2011
- Comparison of Loop-Mediated Isothermal Amplification Assay and Conventional Culture Methods for Detection of Campylobacter jejuni and Campylobacter coli in Naturally Contaminated Chicken Meat SamplesApplied and Environmental Microbiology, 2009
- Shrimp Taura syndrome virus detection by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstickJournal of Virological Methods, 2008
- Loop-mediated isothermal amplification of DNANucleic Acids Research, 2000