Numerical investigation of wall pressure fluctuations downstream of concentric and eccentric blunt stenosis models
Authors:
- 24 October 2019
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (1) , 48-60
Abstract
Pressure fluctuations that cause acoustic radiation from vessel models with concentric and eccentric blunt stenoses are investigated. Large eddy simulations of non-pulsatile flow condition are performed using OpenFOAM. Calculated amplitude and spatial-spectral distribution of acoustic pressures at the post-stenotic region are compared with previous experimental and theoretical results. It is found that increasing the Reynolds number does not change the location of the maximum root mean square wall pressure, but causes a general increase in the spectrum level, although the change in the shape of the spectrum is not significant. On the contrary, compared to the concentric model at the same Reynolds number, eccentricity leads to an increase both at the distance of the location of the maximum root mean square wall pressure from the stenosis exit and the spectrum level. This effect becomes more distinct when radial eccentricity of the stenosis increases. Both the flow rate and the eccentricity of the stenosis shape are evaluated to be clinically important parameters in diagnosing stenosis.Keywords
Funding Information
- Orta Doğu Teknik Üniversitesi (BAP-03-02-2014-001)
This publication has 46 references indexed in Scilit:
- Comparison of LES of Steady Transitional Flow in an Idealized Stenosed Axisymmetric Artery Model With a RANS Transitional ModelJournal of Biomechanical Engineering, 2011
- Brachial artery diameter, blood flow and flow-mediated dilation in sleep-disordered breathingVascular Medicine, 2009
- Assessment Measures for Engineering LES ApplicationsJournal of Fluids Engineering, 2009
- Direct numerical simulation of transitional flow in a stenosed carotid bifurcationJournal of Biomechanics, 2008
- Numerical study of pulsatile flow in a constricted channelJournal of Fluid Mechanics, 2003
- The diameter of the common femoral artery in healthy human: Influence of sex, age, and body sizeJournal of Vascular Surgery, 1999
- Effect of non-Newtonian property of blood on flow through a stenosed tubeFluid Dynamics Research, 1998
- Spectral analysis of arterial bruits (phonoangiography): experimental validation.Circulation, 1980
- Wall vibrations induced by flow through simulated stenoses in models and arteriesJournal of Biomechanics, 1977
- Shear-Layer Flow Regimes and Wave Instabilities and Reattachment Lengths Downstream of an Abrupt Circular Channel ExpansionJournal of Applied Mechanics, 1972