The diagnostic accuracy of imaging modalities to detect pseudarthrosis after spinal fusion—a systematic review and meta-analysis of the literature
Open Access
- 23 February 2019
- journal article
- review article
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (10) , 1499-1510
Abstract
Objective The aim of the study was to determine the diagnostic accuracy of imaging modalities to detect pseudarthrosis after thoracolumbar spinal fusion, with surgical exploration as reference standard. Materials and methods A systematic literature search for original studies was performed on the diagnostic accuracy of imaging as index test compared to surgical exploration as reference standard to diagnose pseudarthrosis after thoracolumbar spinal fusion. Diagnostic accuracy values were extracted and methodologic quality of studies was evaluated by the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Per modality, clinically comparable studies were included in subgroup meta-analysis and weighted odds ratios (ORs) were calculated using the random effects model. Results Fifteen studies were included. Risk of bias was classified as high/unclear in 58% of the studies. Concerns of applicability was classified as high/unclear in 40% of the studies. Four scintigraphy studies including 93 patients in total were pooled to OR = 2.91 (95% confidence interval [CI]: 0.93–9.13). Five studies on plain radiography with 398 patients in total were pooled into OR = 7.07 (95% CI: 2.97–16.86). Two studies evaluating flexion-extension radiography of 75 patients in total were pooled into OR = 4.00 (95% CI: 0.15–105.96). Two studies of 68 patients in total were pooled for CT and yielded OR = 17.02 (95% CI: 6.42–45.10). A single study reporting on polytomography, OR = 10.15 (95% CI 5.49–18.78), was also considered to be an accurate study. Conclusions With a pooled OR of 17.02, CT can be considered the most accurate imaging modality for the detection of pseudarthrosis after thoracolumbar spinal fusion from this review.Keywords
Funding Information
- Maastricht University Medical Center
This publication has 53 references indexed in Scilit:
- Initial investigation of 18F-NaF PET/CT for identification of vertebral sites amenable to surgical revision after spinal fusion surgeryEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- SPECT/CT in Differentiation of Pseudarthrosis From Other Causes of Back Pain in Lumbar Spinal FusionClinical Nuclear Medicine, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the artEuropean Spine Journal, 2009
- Segmental Lumbar LordosisJournal of Spinal Disorders & Techniques, 2004
- Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement SystemSpine, 2000
- Accuracy of SPECT Scanning in Diagnosing PseudoarthrosisJournal of Spinal Disorders, 1998
- Pseudarthrosis of the SpineClinical Orthopaedics and Related Research, 1992
- Results of Lumbosacral Fusion for Degenerative Disc Disease With and Without InstrumentationSpine, 1992
- Lumbar Spinal Fusion Assessment of Functional Stability with Magnetic Resonance ImagingSpine, 1990