Comparison of high‐ and low‐resolution electrospray ionization mass spectrometry for the analysis of naphthenic acid mixtures in oil sands process water
- 19 May 2008
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (12) , 1919-1924
Abstract
The oil sands regions of Northern Alberta, Canada, contain an estimated 1.7 trillion barrels of oil in the form of bitumen, representing the second largest deposit of crude oil in the world. A rapidly expanding industry extracts surface‐mined bitumen using alkaline hot water, resulting in large volumes of oil sands process water (OSPW) that must be contained on site due to toxicity. The toxicity has largely been attributed to naphthenic acids (NAs), a complex mixture of naturally occurring aliphatic and (poly‐)alicyclic carboxylic acids. Research has increasingly focused on the environmental fate and remediation of OSPW NAs, but an understanding of these processes necessitates an analytical method that can accurately characterize and quantify NA mixtures. Here we report results of an interlaboratory comparison for the analysis of pure commercial NAs and environmental OSPW NAs using direct injection electrospray ionization mass spectrometry (ESI‐MS) and high‐pressure liquid chromatography/high‐resolution mass spectrometry (HPLC/HRMS). Both methods provided very similar characterization of pure commercial NA mixture; however, the m/z selectivity of HPLC/HRMS was essential to prevent substantial false‐positive detections and misclassifications in OSPW NA mixtures. For a range of concentrations encompassing those found in OSPW (10–100 mg/L), both methods produced linear response, although concentrations of commercial NAs above 50 mg/L resulted in slight non‐linearity by HPLC/HRMS. A three‐fold lower response factor for total OSPW NAs by HPLC/HRMS was largely attributable to other organic compounds in the OSPW, including hydroxylated NAs, which may explain the substantial misclassification by ESI‐MS. For the quantitative analysis of unknown OSPW samples, both methods yielded total NA concentrations that correlated with results from Fourier transform infrared (FTIR), but the coefficients of determination were not high. Quantification by either MS method should therefore be considered semi‐quantitative at best, albeit either method has substantial value in environmental fate experiments where relative concentration changes are the desired endpoints rather than absolute concentrations. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- Influence of Molecular Structure on the Biodegradability of Naphthenic AcidsEnvironmental Science & Technology, 2008
- Characterization of Naphthenic Acids from Athabasca Oil Sands Using Electrospray Ionization: The Significant Influence of SolventsAnalytical Chemistry, 2007
- Capillary HPLC/QTOF-MS for Characterizing Complex Naphthenic Acid Mixtures and Their Microbial Transformation.Analytical Chemistry, 2006
- Mass spectrometric and toxicological assays of Athabasca oil sands naphthenic acidsWater Research, 2006
- Naphthenic Acids in Athabasca Oil Sands Tailings Waters Are Less Biodegradable than Commercial Naphthenic AcidsEnvironmental Science & Technology, 2005
- A review of the occurrence, analyses, toxicity, and biodegradation of naphthenic acidsChemosphere, 2005
- In Situ Bioremediation of Naphthenic Acids Contaminated Tailing Pond Waters in the Athabasca Oil Sands Region—Demonstrated Field Studies and Plausible Options: A ReviewJournal of Environmental Science and Health, Part A, 2005
- Fourier transform ion cyclotron resonance mass spectrometry of principal components in oilsands naphthenic acidsJournal of Chromatography A, 2004
- Electrospray-Mass Spectrometric Analysis of Reference Carboxylic Acids and Athabasca Oil Sands Naphthenic AcidsAnalytical Chemistry, 2003
- Tandem Mass Spectrometric Characterization of Commercial Naphthenic Acids and a Maya Crude OilEnergy & Fuels, 2002