Five-year Experience with Crossfire?? Highly Cross-linked Polyethylene
Authors:
- James D’antonioJDJames D’antonio
- Michael T ManleyMMMichael T Manley
- William N CapelloWCWilliam N Capello
- Benjamin BierbaumBBBenjamin Bierbaum
- Rama RamakrishnanRRRama Ramakrishnan
- Marybeth NaughtonMNMarybeth Naughton
- Kate SuttonKSKate Sutton
- 1 December 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 441 (&NA;) , 143-150
Abstract
Our purpose was to compare the clinical wear performance of highly cross-linked (Crossfire®) polyethylene with conventional (N2Vac™) polyethylene total hip bearings. We implanted 56 hips (47 patients) with Crossfire® acetabular bearing liners and compared their wear performance with 53 conventional polyethylene inserts. Wear and clinical data were collected retrospectively at a minimum 4-year and average 5-year followup. The linear femoral head penetration rate measured from plain radiographs was 0.055 mm/year ± 0.022 mm/year for the Crossfire® polyethylene and 0.138 mm/year ± 0.073 mm/year for the control, a reduction of 60% for the Crossfire® components. Calculated annual wear was 0.036 mm/year for the Crossfire® components and 0.131mm/year for the controls, a reduction of 72%. Radiographic review at most recent followup showed a reduction in erosive osteolytic lesions of the proximal femur for the Crossfire® components compared with controls, also suggesting a reduction in debris release for the Crossfire® components. Complications leading to revision were not seen in the Crossfire® or control groups. These clinical findings suggest that this particular highly cross-linked polyethylene can provide wear reduction and an alternate bearing surface for active patient populations. Level of Evidence: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 26 references indexed in Scilit:
- Mechanical Properties of Retrieved Highly Cross-Linked Crossfire Liners After Short-Term ImplantationThe Journal of Arthroplasty, 2005
- Alumina Ceramic Bearings for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- In Vivo Wear and Migration of Highly Cross-Linked Polyethylene CupsThe Journal of Arthroplasty, 2005
- Assessing the pattern of femoral head penetration after total hip arthroplastyThe Journal of Arthroplasty, 2004
- SHORT-TERM IN VIVO WEAR OF CROSS-LINKED POLYETHYLENEJournal of Bone and Joint Surgery, 2004
- Patient Factors and Wear in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Comparison of Cross-Linked Polyethylene Materials for Orthopaedic ApplicationsClinical Orthopaedics and Related Research, 2003
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacementsJournal of Orthopaedic Research, 1999
- Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problemBiomaterials, 1996
- An Evaluation of Retrieved UHMWPE Hip Joint CupsJournal of Biomaterials Applications, 1988