Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction
Open Access
- 9 October 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 961-974
Abstract
Purpose: To compare two blind source separation (BSS) techniques to principal component analysis and the electrocardiogram for the identification of cardiac triggers in self‐gated free‐running 5D whole‐heart MRI. To ascertain the precision and robustness of the techniques, they were compared in three different noise and contrast regimes.Methods: The repeated superior–inferior (SI) projections of a 3D radial trajectory were used to extract the physiological signals in three cardiac MRI cohorts: (1) 9 healthy volunteers without contrast agent injection at 1.5T, (2) 30 ferumoxytol‐injected congenital heart disease patients at 1.5T, and (3) 12 gadobutrol‐injected patients with suspected coronary artery disease at 3T. Self‐gated cardiac triggers were extracted with the three algorithms (principal component analysis [PCA], second‐order blind identification [SOBI], and independent component analysis [ICA]) and the difference with the electrocardiogram triggers was calculated. PCA and SOBI triggers were retained for image reconstruction. The image sharpness was ascertained on whole‐heart 5D images obtained with PCA and SOBI and compared among the three cohorts.Results: SOBI resulted in smaller trigger differences in Cohorts 1 and 3 compared to PCA (p < 0.01) and in all cohorts compared to ICA (p < 0.04). In Cohorts 1 and 3, the sharpness increased significantly in the reconstructed images when using SOBI instead of PCA (p < 0.03), but not in Cohort 2 (p = 0.4).Conclusion: We have shown that SOBI results in more precisely extracted self‐gated triggers than PCA and ICA. The validation across three diverse cohorts demonstrates the robustness of the method against acquisition variability.Keywords
Funding Information
- Schweizerische Herzstiftung (FF23129)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (310030_215604, 320030B_201292, 32003B_182615, PZ00P3_202140)
This publication has 29 references indexed in Scilit:
- Self‐gated golden angle spiral cine MRI for coronary endothelial function assessmentMagnetic Resonance in Medicine, 2017
- Flexible water excitation for fat‐free MRI at 3T using lipid insensitive binomial off‐resonant RF excitation (LIBRE) pulsesMagnetic Resonance in Medicine, 2017
- 5D whole‐heart sparse MRIMagnetic Resonance in Medicine, 2017
- Edge sharpness assessment by parametric modeling: Application to magnetic resonance imagingConcepts in Magnetic Resonance Part A, 2015
- XD‐GRASP: Golden‐angle radial MRI with reconstruction of extra motion‐state dimensions using compressed sensingMagnetic Resonance in Medicine, 2015
- Free‐running 4D whole‐heart self‐navigated golden angle MRI: Initial resultsMagnetic Resonance in Medicine, 2014
- ECG and navigator‐free four‐dimensional whole‐heart coronary MRA for simultaneous visualization of cardiac anatomy and functionMagnetic Resonance in Medicine, 2014
- Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRIMagnetic Resonance in Medicine, 2011
- Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRIMagnetic Resonance in Medicine, 2004
- Self‐gated cardiac cine MRIMagnetic Resonance in Medicine, 2003