Analysis of complex mixtures of triglycerides that span a broad range of partition numbers can entail a number of difficulties. The present study was therefore intended to develop a method of reverse‐phase high‐performance liquid chromatography using a light scattering detector for analyzing such mixtures. Stationary phase type, mobile phase gradient, column temperature, and injection solvent were the factors used to develop the method. The method improved the selectivity of critical pairs of milk fat triglycerides, providing good resolution for 115 peaks with partition numbers of between 22 and 53. The use of tristearin as internal standard and the relative response factors for different partition number ranges made it possible to more accurately estimate the weight of the sample triglycerides.Keywords
This publication has 32 references indexed in Scilit:
- Silver ion and chiral chromatography in the analysis of tricylglycerolsProgress in Lipid Research, 1994
- Comparison of the Evaporative Light Scattering Detector (ELSD) and Refractive Index Detector (RID) in Lipid AnalysisJournal of Liquid Chromatography, 1993
- Evaluation instrumentale et sensorielle de certaines propriétés texturales de fromages à pâte molleInternational Dairy Journal, 1993
- Separation of highly unsaturated triacylglycerols by reversed phase HPLC with short wavelength UV detectionJournal of High Resolution Chromatography, 1992
- HPLC and GLC analysis of the triglyceride composition of bovine, ovine and caprine milk fatJournal of Dairy Research, 1990
- Effects of the Nature of the Solvent and Solutes on the Response of a Light-Scattering DetectorJournal of Liquid Chromatography, 1988
- Influence of Bonded-Phase Column Type, Mobile Phase Composition, Temperature and Flow-Rate in the Analysis of Triglycerides by Reverse-Phase High Performance Liquid ChromatographyJournal of Liquid Chromatography, 1987
- Analysis of Lipid Classes by HPLC with the Evaporative Light Scattering DetectorJournal of Liquid Chromatography, 1987
- Analysis of triglycerides in oils and fats by liquid chromatography with the laser light scattering detectorAnalytical Chemistry, 1985
- HPLC‐Trennung von TriglyceridenFette, Seifen, Anstrichmittel, 1985