MRI-Guided Breast Biopsy: Influence of Choice of Vacuum Biopsy System on the Mode of Biopsy of MRI-Only Suspicious Breast Lesions
- 1 June 2010
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 194 (6) , 1650-1657
Abstract
OBJECTIVE. The purpose of this study was to evaluate two systems of MRI-guided vacuum-assisted biopsy and to investigate the influence of the choice of system on the choice of biopsy mode in the care of patients with lesions found only at MRI. MATERIALS AND METHODS. Over a period of 3 years, a total 349 patients underwent MRI-guided tissue sampling of 475 lesions found only at MRI. The lesions were sampled by needle localization plus excisional biopsy or by vacuum-assisted biopsy. Two different systems were used for MRI-guided vacuum-assisted biopsy. During the first half of the study period, a handheld system was used, and during the second half, a console system was used. The procedural advantages and disadvantages, size of lesions biopsied, and time needed for vacuum-assisted biopsy were recorded. The distribution of the type of intervention (needle localization or vacuum-assisted biopsy) used to manage MRI-only lesions during the two study periods also was assessed. RESULTS. The average diameter of lesions sampled with vacuum-assisted biopsy was 19.2 mm with the handheld system and 10.4 mm with the console system (p < 0.039). The average biopsy time was 69 minutes for the handheld system and 39 minutes for the console system (p < 0.005). Of the total of 170 MRI-only lesions biopsied with the handheld system, 121 (71%) were sampled by localization and 49 (29%) by vacuum-assisted biopsy. Of the total 305 MRI-only lesions biopsied with the console system, 38 (12%) were sampled by localization and 267 (88%) by vacuum-assisted biopsy. CONCLUSION. Because of the procedural advantages of use of the console-based system, smaller lesions were biopsied in less time and with higher operator confidence. This result translated into a major shift in the care of patients with MRI-only lesions away from lesion localization toward increased use of MRI-guided vacuum-assisted biopsy.Keywords
This publication has 18 references indexed in Scilit:
- Current Status of Breast MR Imaging Part 2. Clinical ApplicationsRadiology, 2007
- Diagnostic Breast MR Imaging: Current Status and Future DirectionsRadiologic Clinics of North America, 2007
- Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy deviceActa Radiologica, 2006
- Magnetic resonance‐guided, vacuum‐assisted breast biopsyCancer, 2006
- MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy NeedleAmerican Journal of Roentgenology, 2004
- MR Imaging—Guided Breast Biopsy Using a Coaxial Technique with a 14-Gauge Stainless Steel Core Biopsy Needle and a Titanium SheathAmerican Journal of Roentgenology, 2003
- European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluationEuropean Radiology, 2002
- MR Imaging–guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging AloneRadiology, 2001
- Percutaneous Imaging-Guided Core Breast BiopsyAmerican Journal of Roentgenology, 2000
- MR-guided biopsy of suspect breast lesions with a simple stereotaxic add-on-device for surface coils.Radiology, 1994