Ultrafast Electrothermal Flow‐Enhanced Magneto Biosensor for Highly Sensitive Protein Detection in Whole Blood
- 30 March 2022
- journal article
- research article
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 61 (22) , e202200206
Abstract
Current diagnostic tests for sensitive protein detection rely on immunological techniques, such as ELISA, which require sample purification, multiple washing steps and lengthy incubation, hindering their use for rapid testing. Here, we report a simple electrothermal flow‐enhanced biosensor for ultrafast, high sensitivity measurements of protein biomarkers in whole blood. Magnetic nanobeads dually‐labeled with a detection antibody and enzyme reporter are used to form immunocomplexes with the target protein, which are readily transported to the sensor via magnetic concentration. The incorporation of electrothermal flows enhances immunocomplex formation, allowing for rapid and sensitive detection without requiring blood purification or lengthy incubation. Proof of concept was carried out using Plasmodium falciparum histidine‐rich protein 2 ( Pf HRP2), a malaria parasite biomarker, which could be detected at concentrations as low as 5.7 pg mL −1 (95 fM) in whole blood in 7 min. The speed, sensitivity and simplicity of this device make it attractive for rapid diagnostic testing.Keywords
Funding Information
- National Institutes of Health (R01AI113257)
This publication has 50 references indexed in Scilit:
- Plasma Biomarkers as Predictors of Outcome in Patients with Advanced Hepatocellular CarcinomaClinical Cancer Research, 2012
- In Situ Electrokinetic Enhancement for Self-Assembled-Monolayer-Based Electrochemical BiosensingAnalytical Chemistry, 2012
- Matrix Effects—A Challenge toward Automation of Molecular AnalysisSLAS Technology, 2010
- Electrothermal stirring for heterogeneous immunoassaysLab on a Chip, 2005
- Protein–protein unbinding induced by force: single-molecule studiesCurrent Opinion in Structural Biology, 2003
- A rapid diffusion immunoassay in a T-sensorNature Biotechnology, 2001
- Ac electrokinetics: a review of forces in microelectrode structuresJournal of Physics D: Applied Physics, 1998
- Simulation of detachment of specifically bound particles from surfaces by shear flowBiophysical Journal, 1997
- Relationship between receptor/ligand binding affinity and adhesion strengthBiophysical Journal, 1993
- Measurement of Prostate-Specific Antigen in Serum as a Screening Test for Prostate CancerThe New England journal of medicine, 1991