Ultrahigh-Density 256-Channel Neural Sensing Microsystem Using TSV-Embedded Neural Probes
Authors:
- 30 March 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 11 (5) , 1013-1025
Abstract
Highly integrated neural sensing microsystems are crucial to capture accurate signals for brain function investigations. In this paper, a 256-channel neural sensing microsystem with a sensing area of 5 × 5 mm 2 is presented based on 2.5-D through-silicon-via (TSV) integration. This microsystem composes of dissolvable μ-needles, TSV-embedded μ-probes, 256-channel neural amplifiers, 11-bit area-power-efficient successive approximation register analog-to-digital converters, and serializers. This microsystem can detect 256 electrocorticography and local field potential signals within a small area of 5 mm × 5 mm. The neural amplifier realizes 57.8 dB gain with only 9.8 μW per channel. The overall power of this microsystem is only 3.79 mW for 256-channel neural sensing. A smaller microsystem with dimension of 6 mm × 4 mm has been also implanted into rat brain for somatosensory evoked potentials (SSEPs) recording by using contralateral and ipsilateral electrical stimuli with intensity from 0.2 to 1.0 mA, and successfully observed different SSEPs from left somatosensory cortex of a rat.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan, R.O.C. (MOST 103-2221-E-009-192-MY3, MOST 105-2218-E-009-018)
This publication has 24 references indexed in Scilit:
- An 8-channel chopper-stabilized analog front-end amplifier for EEG acquisition in 65-nm CMOS2015
- A Novel Flexible 3-D Heterogeneous Integration Scheme Using Electroless Plating on Chips With Advanced Technology NodeIEEE Transactions on Electron Devices, 2015
- A Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural InterfacesJournal of Low Power Electronics and Applications, 2014
- 320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive NeurostimulationIEEE Transactions on Biomedical Circuits and Systems, 2014
- Backside-Process-Induced Junction Leakage and Process Improvement of Cu TSV Based on Cu/Sn and BCB Hybrid BondingIEEE Electron Device Letters, 2013
- A 4 $\mu{\rm W}/{\rm Ch}$ Analog Front-End Module With Moderate Inversion and Power-Scalable Sampling Operation for 3-D Neural MicrosystemsIEEE Transactions on Biomedical Circuits and Systems, 2012
- The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation InterfaceIEEE Transactions on Biomedical Circuits and Systems, 2010
- Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recordingJournal of Micromechanics and Microengineering, 2009
- Microelectrodes, Microelectronics, and Implantable Neural MicrosystemsProceedings of the IEEE, 2008
- Microelectrode Array Fabrication by Electrical Discharge Machining and Chemical EtchingIEEE Transactions on Biomedical Engineering, 2004