Quantifying Valve Regurgitation Using 3-D Doppler Ultrasound Images and Deep Learning
Open Access
- 31 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3317-3326
Abstract
Accurate quantification of cardiac valve regurgitation jets is fundamental for guiding treatment. Cardiac ultrasound is the preferred diagnostic tool, but current methods for measuring the regurgitant volume (RVol) are limited by low accuracy and high interobserver variability. Following recent research, quantitative estimators of orifice size and RVol based on high frame rate 3-D ultrasound have been proposed, but measurement accuracy is limited by the wide point spread function (PSF) relative to the orifice size. The aim of this article was to investigate the use of deep learning to estimate both the orifice size and the RVol. A simulation model was developed to simulate the power-Doppler images of blood flow through orifices with different geometries. A convolutional neural network (CNN) was trained on 30 000 image pairs. The network was used to reconstruct orifices from power-Doppler data, which facilitated estimators for regurgitant orifice areas and flow volumes. We demonstrate that the network improves orifice shape reconstruction, as well as the accuracy of orifice area and flow volume estimation, compared with a previous approach based on thresholding of the power-Doppler signal (THD), and compared with spatially invariant deconvolution (DC). Our approach reduces the area estimation error on simulations: (THD: 13.2 ± 9.9 mm2, DC: 12.8 ± 15.8 mm2, and ours: 3.5 ± 3.2 mm2). In a phantom experiment, our approach reduces both area estimation error (THD: 10.4 ± 8.4 mm2, DC: 10.98 ± 8.17, and ours: 9.9 ± 6.0 mm2) and flow rate estimation error (THD: 20.3 ± 9.9 ml/s, DC: 18.14 ± 13.01 ml/s, and ours: 7.1 ± 10.6 ml/s). We also demonstrate in vivo feasibility for six patients with aortic insufficiency, compared with standard echocardiography and magnetic resonance references.Keywords
Funding Information
- Centre for Innovative Ultrasound Solutions (CIUS), a centre for research-based innovation appointed by the Norwegian Research Council
This publication has 33 references indexed in Scilit:
- Point spread functions and deconvolution of ultrasonic imagesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Reproducibility of Proximal Isovelocity Surface Area, Vena Contracta, and Regurgitant Jet Area for Assessment of Mitral Regurgitation SeverityJACC: Cardiovascular Imaging, 2010
- Intraobserver variability in grading severity of repeated identical cases of mitral regurgitationAmerican Heart Journal, 2008
- Direct Assessment of Size and Shape of Noncircular Vena Contracta Area in Functional Versus Organic Mitral Regurgitation Using Real-Time Three-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 2008
- Effect of Dynamic Flow Rate and Orifice Area on Mitral Regurgitant Stroke Volume Quantification Using the Proximal Isovelocity Surface Area MethodJACC, 2008
- Burden of valvular heart diseases: a population-based studyThe Lancet, 2006
- Prevalence and clinical determinants of mitral, tricuspid, and aortic regurgitation (the Framingham Heart Study)The American Journal of Cardiology, 1999
- Insights From Three-Dimensional Echocardiography Into the Mechanism of Functional Mitral RegurgitationCirculation, 1997
- A new method for quantitation of mitral regurgitation based on color flow Doppler imaging of flow convergence proximal to regurgitant orifice.Circulation, 1991
- An iterative technique for the rectification of observed distributionsThe Astronomical Journal, 1974