Sorption of his-tagged Protein G and Protein G onto chitosan/divalent metal ion sorbent used for detection of microcystin-LR
- 15 December 2015
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (1) , 15-24
Abstract
A highly sensitive, specific, simple, and rapid chemiluminescence enzyme immunoassay (CLEIA) was developed for the determination of microcystin-LR (MC-LR) by using strategies for oriented immobilization of functionally intact polyclonal antibodies on chitosan surface. Several physicochemical parameters such as metal ion adsorption, hexahistidine-tagged Protein G sorption, the dilution ratio polyclonal antibody concentration, and peroxidase-labeled MC-LR concentration were studied and optimized. The sorption in batch system of G-histidine and G-proteins was studied on a novel sorbent consisting of chitosan/divalent metal ions. Transition metals as Ni++ and Zn++ were immobilized through interaction with –NH2 groups of chitosan in order to supply a material capable to efficiently remove the proteins from aqueous solutions. The maximum uptake of divalent metals onto the chitosan material was found to be 230 mg g−1 for Zn++ and 62 mg g−1 for Ni++. Experimental data were evaluated using the Langmuir and Freundlich models; the results were well fitted with the Langmuir model; chitosan/Ni++ foam was found to be the best sorbent for G-protein, maximum sorption capacity obtained was 17 mg g−1, and chitosan/Zn++ was found to be the best for G-histidine with a maximum sorption capacity of 44 mg g−1. Kinetic data was evaluated with pseudo-first- and pseudo-second-order models; the sorption kinetics were in all cases better represented by a pseudo-second-order model. Under optimum conditions, the calibration curve obtained for MC-LR gave detection limits of 0.5 ± 0.06 μg L−1, the 50 % inhibition concentration (IC50) was 2.75 ± 0.03 μg L−1, and the quantitative detection range was 0.5–25 μg L−1. The limit of detection (LOD) attained from the calibration curves and the results obtained demonstrate the potential use of CLEIA with chitosan support as a screening tool for the analysis of pollutants in environmental samples.Keywords
This publication has 38 references indexed in Scilit:
- Site-directed antibody immobilization techniques for immunosensorsBiosensors and Bioelectronics, 2013
- Adsorption of copper (II) and lead (II) ions from aqueous solution on chitosan-coated sandCarbohydrate Polymers, 2010
- High-dose hook effect in prolactin macroadenomas: A diagnostic concernJournal of Human Reproductive Sciences, 2010
- Highly sensitive amperometric immunosensors for microcystin detection in algaeBiosensors and Bioelectronics, 2007
- Evaluating genotoxicity associated with microcystin-LR and its risk to source water safety in Meiliang Bay, Taihu LakeEnvironmental Toxicology, 2006
- Controlling the orientation of immobilized proteins on an affinity membrane through chelation of a histidine tag to a chitosan-Ni++ surfaceJournal of Membrane Science, 2006
- Adsorption of boron from aqueous solutions using fly ash: Batch and column studiesJournal of Hazardous Materials, 2005
- Detection of the cyanobacterial hepatotoxins microcystinsToxicology and Applied Pharmacology, 2005
- Engineered Protein A for the Orientational Control of Immobilized ProteinsBioconjugate Chemistry, 2003
- Adsorption of direct red 12 B by biogas residual slurry: Equilibrium and rate processesEnvironmental Pollution, 1995