Abstract
This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Clarion patients was also compared with a group of patients who were using either the feature-extraction Nucleus cochlear implant or the compressed-analog Ineraid cochlear implant. One aim was to compare the analog and pulsatile stimulation in 19 patients using the Clarion implant. This aim could be accomplished only partially because of difficulties encountered in adequately fitting patients with the analog strategy. A second aim was to compare the Clarion users' performance with feature-extraction Nucleus and compressed-analog Ineraid patients. Comparisons were made with all patients having 9 mo experience postimplantation. Subjects performed better using the pulsatile mode compared with the analog mode. All subjects chose to use the pulsatile strategy after the first 3 mo of the study. Results comparing performance at 9 mo with our compressed-analog Ineraid and feature-extraction Nucleus patients indicated, in general, better average performance for the Clarion users. We conclude that the pulsatile version of the Clarion cochlear implant typically produces superior performance to the analog version of that device at this stage in its development. After 9 mo of experience, users of the Clarion implant are performing better than are users of the feature-extraction Nucleus and compressed-analog Ineraid cochlear implants with comparable amounts of experience.Keywords
This publication has 12 references indexed in Scilit:
- A Within-Subject Comparison of Adult Patients Using the Nucleus F0F1F2 and F0F1F2B3B4B5 Speech Processing StrategiesJournal of Speech, Language, and Hearing Research, 1996
- Perceptual Performance of Subjects with Cochlear Implants Using the Spectral Maxima Sound Processor (SMSP) and the Mini Speech Processor (MSP)Ear & Hearing, 1993
- The Nucleus 22-Channel Cochlear Implant SystemEar & Hearing, 1991
- Performance of Postlinguistically Deaf Adults with the Wearable Speech Processor (WSP III) and Mini Speech Processor (MSP) of the Nucleus Multi-Electrode Cochlear Implant*Ear & Hearing, 1991
- Longitudinal Changes in Word Recognition by Patients Who Use the Ineraid Cochlear ImplantEar & Hearing, 1990
- Electrically evoked whole-nerve action potentials: Data from human cochlear implant usersThe Journal of the Acoustical Society of America, 1990
- The ucsf/storz multichannel cochlear implant: patient resultsThe Laryngoscope, 1986
- Multichannel Cochlear Implants: Channel Interactions and Processor DesignJAMA Otolaryngology–Head & Neck Surgery, 1984
- Speech discrimination in deaf subjects with cochlear implantsThe Journal of the Acoustical Society of America, 1980
- Speech-Discrimination Scores Modeled as a Binomial VariableJournal of Speech and Hearing Research, 1978