Abstract
Several linked total elbow arthroplasty designs exist, which function similar to a loose hinge joint. Constraint behaviour is an important design consideration, as it affects joint stability, or how much secondary [e.g. varus–valgus (VV)] motion is permitted. Implant durability is also a concern, as bearing failures have been reported. This finite element analysis investigates the constraint characteristics and ultra high molecular weight polyethylene bearing stresses of three linked elbow design concepts [cylindrical (CY), hourglass (HG) and concave cylinder (CC)]. The bearing of the CY design was subjected to elevated Von Mises stresses (2.1–5.4 times higher than the HG and CC designs) due to edge loading. The HG design maintained low stresses, but was unable to provide consistent VV stability. The CC design also maintained low stresses while providing consistent VV stability. These results suggest that CC designs may provide better stability characteristics and durability in vivo, compared to the other two designs.Keywords
This publication has 20 references indexed in Scilit:
- Total Elbow ArthroplastyThe Open Orthopaedics Journal, 2011
- Results after 562 total elbow replacements: A report from the Norwegian Arthroplasty RegisterJournal of Shoulder and Elbow Surgery, 2009
- Total Hip Wear Assessment: A Comparison Between Computational and In Vitro Wear Assessment Techniques Using ISO 14242 Loading and KinematicsJournal of Biomechanical Engineering, 2009
- Total elbow arthroplasty with the Coonrad/Coonrad-Morrey prosthesisThe Journal of Bone and Joint Surgery. British volume, 2006
- Intrinsic Constraint of Unlinked Total Elbow Replacements—The Ulnotrochlear JointJournal of Bone and Joint Surgery, 2005
- Explicit finite element modeling of total knee replacement mechanicsJournal of Biomechanics, 2005
- Shapes and dimensional characteristics of polyethylene wear particles generatedin vivo by total knee replacements compared to total hip replacementsJournal of Biomedical Materials Research, 1997
- Loose-hinge total elbow arthroplastyThe Journal of Arthroplasty, 1995
- Osteolysis of the distal femur after total knee arthroplastyThe Journal of Arthroplasty, 1994
- The production and biology of polyethylene wear debrisArchives of orthopaedic and trauma surgery, 1978