Acoustic Analysis of Condenser Fan of Split Air Conditioner Using Numerical and Experimental Method
Authors:
- 27 May 2015
- journal article
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 23 (02)
Abstract
The present work aims to investigate the accurate method of performing computational fluid dynamics (CFD) — Acoustic analysis for axial flow fans in split air conditioner system. A comprehensive simulation procedure is developed to predict flow-induced noise in a system. The three-dimensional domain using k–ε turbulence model and Ffowcs Williams and Hawkings (FW-H) acoustic model is considered to predict noise generated by the fan blade surface. The acoustic and flow performances of the fan are predicted simultaneously using a computational aero-acoustic technique (combining steady flow and noise propagation analysis). The different cases are simulated by varying the blade angle, blade depth, blade width and serrations at trailing edge of fan blade. An impact of each of these parameter on A-weighted sound pressure level (SPL) and mass flow rate at outlet is determined. The numeric value of obtained A-weighted SPL by CFD simulation is found to be in close agreement with the experimental result within 5.4%. Finally, above mentioned parameters are varied in simulation and optimized design is proposed based on A-weighted SPL and cubic feet per minute (CFM). All simulations are carried out in commercially available CFD solver; ANSYS FLUENT 13.Keywords
This publication has 16 references indexed in Scilit:
- INFLUENCE OF GEOMETRIC PARAMETERS ON CENTRIFUGAL FAN PERFORMANCE AND ITS SIGNIFICANCE IN AUTOMOTIVE APPLICATIONSInternational Journal of Modeling, Simulation, and Scientific Computing, 2012
- Reduction of motor fan noise using CFD and CAA simulationsApplied Acoustics, 2011
- 3D Modelling and Analysis Flow of Air Conditioner Outdoor Fan for Cost ReductionAdvanced Materials Research, 2011
- A STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADEInternational Journal of Air-Conditioning and Refrigeration, 2010
- Experimental and numerical study on aerodynamic noise of outdoor unit of room air conditioner with different grillesInternational Journal of Refrigeration, 2009
- Experimental and numerical study on aeroacoustic sound of axial flow fan in room air conditionerApplied Acoustics, 2007
- Effect of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditionerApplied Thermal Engineering, 2006
- Experimental determination of the tonal noise sources in a centrifugal fanJournal of Sound and Vibration, 2006
- Identification of noise sources on a residential split-system air-conditioner using sound intensity measurementsApplied Acoustics, 2004
- Aerodynamic noise of a serrated trailing edgeJournal of Fluids and Structures, 1991