A Multi-Channel Continuous Water Toxicity Monitoring System: Its Evaluation and Application to Water Discharged from a Power Plant
Authors:
- 1 October 2005
- journal article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 109 (1-3) , 123-133
Abstract
A multi-channel continuous water toxicity monitoring system was, after confirming the systems' performance, implemented to samples of water discharged from power plants to detect and classify their toxicity using several recombinant bioluminescent bacteria. Each channel of the system is composed of a series of two mini-bioreactors to enable a continuous operation, i.e., without system interruption due to highly toxic samples. A different recombinant bacterial strain was present in each channel: DPD2540 (fabA::lux CDABE), DPD2794 (recA::luxCDABE), and TV1061 (grpE::luxCDABE), which are induced by cell membrane-, DNA-, and protein-damaging agents, respectively. GC2 (lac::luxCDABE) is a constitutive strain, whose bioluminescence is reduced by an increase in cellular toxicity. Phenol and mitomycin C (MMC) were used for evaluating the system's performance to detect toxic chemicals. These samples were injected into the second mini-bioreactor according to a step or bell-curve manner. The field samples used in this study were obtained from the water discharged from two different power plants in Korea – from a nuclear power plant and a thermo-electronic power plant, and were injected into the second mini-bioreactor to initiate the toxicity test. Each channel showed specific bioluminescent (BL) response profiles due to the toxic compounds present in the water samples. Comparing the BL signals between the standard toxic chemical samples and discharged water samples, the equivalent toxicity of the field water could be estimated. Finally, it was proved that this novel continuous toxicity monitoring system can be used as an alternative tool for the quick monitoring and control of water quality, as well as aid in the setting up of a new monitoring strategy to protect the source of tap water and in the prevention of polluted water discharge.Keywords
This publication has 15 references indexed in Scilit:
- Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassayBiosensors and Bioelectronics, 2003
- Response of bioluminescent bacteria to sixteen azo dyesBiotechnology and Bioprocess Engineering, 2003
- A multi-channel continuous toxicity monitoring system using recombinant bioluminescent bacteria for classification of toxicityBiosensors and Bioelectronics, 2001
- Using higher organisms in biological early warning systems for real-time toxicity detectionBiosensors and Bioelectronics, 2001
- Cloning and sequencing of a gene encoding a novel salt stress-induced membrane protein from Rhodobacter sphaeroides f. sp. denitrificansApplied Microbiology and Biotechnology, 2001
- The Continuous Monitoring of Field Water Samples with a Novel Multi-Channel Two-Stage Mini-Bioreactor SystemEnvironmental Monitoring and Assessment, 2001
- Unsaturated Fatty Acids in Membrane Lipids Protect the Photosynthetic Machinery against Salt-Induced Damage inSynechococcusPlant Physiology, 2001
- Monitoring and classification of toxicity using recombinant bioluminescent bacteriaWater Science & Technology, 2001
- A panel of stress-responsive luminous bacteria for the detection of selected classes of toxicantsWater Research, 1997
- Monitoring the Biological Effects of Chemicals in River Water using Daphnia magna.NIPPON SUISAN GAKKAISHI, 1997