Bedside Allogeneic Erythrocyte Washing with a Cell Saver to Remove Cytokines, Chemokines, and Cell-derived Microvesicles
Authors:
Open Access
- 1 March 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 134 (3) , 395-404
Abstract
Background: Removal of cytokines, chemokines, and microvesicles from the supernatant of allogeneic erythrocytes may help mitigate adverse transfusion reactions. Blood bank–based washing procedures present logistical difficulties; therefore, we tested the hypothesis that on-demand bedside washing of allogeneic erythrocyte units is capable of removing soluble factors and is feasible in a clinical setting. Methods: There were in vitro and prospective, observation cohort components to this a priori planned substudy evaluating bedside allogeneic erythrocyte washing, with a cell saver, during cardiac surgery. Laboratory data were collected from the first 75 washed units given to a subset of patients nested in the intervention arm of a parent clinical trial. Paired pre- and postwash samples from the blood unit bags were centrifuged. The supernatant was aspirated and frozen at –70°C, then batch-tested for cell-derived microvesicles, soluble CD40 ligand, chemokine ligand 5, and neutral lipids (all previously associated with transfusion reactions) and cell-free hemoglobin (possibly increased by washing). From the entire cohort randomized to the intervention arm of the trial, bedside washing was defined as feasible if at least 75% of prescribed units were washed per protocol. Results: Paired data were available for 74 units. Washing reduced soluble CD40 ligand (median [interquartile range]; from 143 [1 to 338] ng/ml to zero), chemokine ligand 5 (from 1,314 [715 to 2,551] to 305 [179 to 488] ng/ml), and microvesicle numbers (from 6.90 [4.10 to 20.0] to 0.83 [0.33 to 2.80] × 106), while cell-free hemoglobin concentration increased from 72.6 (53.6 to 171.6) mg/dl to 210.5 (126.6 to 479.6) mg/dl (P < 0.0001 for each). There was no effect on neutral lipids. Bedside washing was determined as feasible for 80 of 81 patients (99%); overall, 293 of 314 (93%) units were washed per protocol. Conclusions: Bedside erythrocyte washing was clinically feasible and greatly reduced concentrations of soluble factors thought to be associated with transfusion-related adverse reactions, increasing concentrations of cell-free hemoglobin while maintaining acceptable (less than 0.8%) hemolysis. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:Keywords
This publication has 46 references indexed in Scilit:
- Platelet‐ and erythrocyte‐derived microparticles trigger thrombin generation via factor XIIaJournal of Thrombosis and Haemostasis, 2012
- Disruption of Platelet-derived Chemokine Heteromers Prevents Neutrophil Extravasation in Acute Lung InjuryAmerican Journal of Respiratory and Critical Care Medicine, 2012
- Nitric Oxide Scavenging by Red Blood Cell Microparticles and Cell-Free Hemoglobin as a Mechanism for the Red Cell Storage LesionCirculation, 2011
- An association between decreased cardiopulmonary complications (transfusion‐related acute lung injury and transfusion‐associated circulatory overload) and implementation of universal leukoreduction of blood transfusionsTransfusion, 2010
- Hemolysis of red blood cells after cell washing with different automated technologies: clinical implications in a neonatal cardiac surgery populationTransfusion, 2010
- Cardiac Arrests Associated with Hyperkalemia During Red Blood Cell Transfusion: A Case SeriesAnesthesia & Analgesia, 2008
- Processing of stored packed red blood cells using autotransfusion devices decreases potassium and microaggregates: a prospective, randomized, single‐blinded in vitro studyTransfusion Medicine, 2007
- Soluble CD40 ligand accumulates in stored blood components, primes neutrophils through CD40, and is a potential cofactor in the development of transfusion-related acute lung injuryBlood, 2006
- Intraoperative Washing of Long-Stored Packed Red Blood Cells by Using an Autotransfusion Device Prevents HyperkalemiaAnesthesia & Analgesia, 2002
- Intraoperative Washing of Long-Stored Packed Red Blood Cells by Using an Autotransfusion Device Prevents HyperkalemiaAnesthesia & Analgesia, 2002