Influence of heat and moisture exchanger use on measurements performed with manovacuometer and respirometer in healthy adults
Open Access
- 19 December 2015
- journal article
- research article
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 11 (1) , 1-6
Abstract
The use of evaluation tools such as the manovacuometer and respirometer is frequent and disinfection is usually limited to the external surfaces, which is insufficient and raises concerns because of the potential spread of infectious diseases. Hydrophobic heat and moisture exchangers (HME) are used in mechanical ventilation and have microbiological filters, which can possibly reduce contamination, increasing the safety of related procedures. It is unknown, however, if the addition of an exchanger affects the measurements obtained. Aim of this study was to verify if the use of an HME interferes in maximal inspiratory and expiratory pressures assessed using the manovacuometer and vital capacity evaluated using the respirometer in healthy adults. A controlled transversal trial was carried out. Twenty healthy young adults were included in the study. Vital capacity by respirometer and, maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) were assessed with and without the use of HME. No significant difference was found between the values pre and post HME use in vital capacity measurements: (3878.8 ± 202.2 mL vs. 3925.5 ± 206.0 mL, p = 0.116) and the respiratory muscle strength measurements: MIP (−99.0 ± 8.9 vs −95.5 ± 9.0 cm H2O, p = 0.149) and MEP (92.5 ± 7.5 vs 92.5 ± 7.7 cm H2O, p = 1.0) respectively. We conclude that the use of HME does not modify the lung volumes or respiratory muscle strength, and can be used in order to reduce the occurrence of pulmonary infection.Keywords
This publication has 23 references indexed in Scilit:
- Estimation of lung vital capacity before and after coronary artery bypass grafting surgery: a comparison of incentive spirometer and ventilometryJournal of Cardiothoracic Surgery, 2011
- Effects of 8-Week, Interval-Based Inspiratory Muscle Training and Breathing Retraining in Patients With Generalized Myasthenia GravisChest, 2005
- ATS/ERS Statement on Respiratory Muscle TestingAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Respiratory Muscle Evaluation of the Patient with Neuromuscular DiseaseSeminars in Respiratory and Critical Care Medicine, 2002
- Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized studyCritical Care Medicine, 2000
- Efficiency and Safety of Mechanical Ventilation with a Heat and Moisture Exchanger Changed Only Once a WeekAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Safety of Combined Heat and Moisture Exchanger Filters in Long-term Mechanical VentilationChest, 1997
- Resistive pressure of a condenser humidifier in mechanically ventilated patientsCritical Care Medicine, 1994
- Performance Evaluation of Three Vaporizing Humidifiers and Two Heat and Moisture Exchangers in Patients with Minute Ventilation <10 L/minChest, 1992
- Pressure Flow Characteristics of Commonly Used Heat-Moisture ExchangersAmerican Review of Respiratory Disease, 1988