Renal Perfusion 3-T MR Imaging: A Comparative Study of Arterial Spin Labeling and Dynamic Contrast-enhanced Techniques
- 1 December 2011
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 261 (3) , 845-853
Abstract
To investigate the feasibility of and correlation between arterial spin-labeling (ASL) and dynamic contrast material-enhanced (DCE) 3-T magnetic resonance (MR) imaging in the measurement of renal blood flow (RBF). The review board approved this study. Nineteen healthy volunteers (seven women, 12 men; age range, 25-68 years) were recruited, and each provided written informed consent. MR imaging was performed with a 3-T whole-body system. Each subject underwent back-to-back ASL and DCE MR imaging. Ten runs of ASL imaging were performed by using the pseudocontinuous tagging scheme, and each run required an 18-second breath hold. For DCE imaging, a gadopentetate dimeglumine bolus (0.0125 mmol per kilogram of body weight) was administrated intravenously in all subjects except two; in the latter subjects, a 0.025 mmol/kg gadopentetate dimeglumine bolus was administered to evaluate the T1 saturation effect. RBF was quantified with both techniques and in both the cortex and the medulla. Agreement was evaluated for RBF measurements obtained with ASL imaging and those obtained with DCE imaging by using correlation analysis. RBF was apparently overestimated with 0.025 mmol/kg gadopentetate dimeglumine, which is a concentration that is commonly adopted for 1.5-T DCE. RBF was 227 mL/100 mL/min ± 30 (standard deviation) in the cortex and 101 mL/100 mL/min ± 21 in the medulla, as measured with ASL imaging, and 272 mL/100 mL/min ± 60 in the cortex and 122 mL/100 mL/min ± 30 in the medulla, as measured with DCE imaging. In the cortex, measurements obtained with ASL and DCE imaging exhibited a linear correlation (r = 0.66; statistical power, 0.8 at the 5% significance level) and fair agreement (intraclass correlation coefficient, 0.41). ASL and DCE 3-T MR imaging are feasible in the quantification of cortical renal perfusion, yielding measurements that are correlated but not entirely comparable. Intermodality differences have yet to be solved.Keywords
This publication has 29 references indexed in Scilit:
- Metastatic Renal Carcinoma: Evaluation of Antiangiogenic Therapy with Dynamic Contrast-enhanced CTRadiology, 2010
- Assessment of Chronic Renal Allograft Nephropathy Using Contrast-Enhanced MRI: A Pilot StudyAmerican Journal of Roentgenology, 2010
- Multislice perfusion of the kidneys using parallel imaging: Image acquisition and analysis strategiesMagnetic Resonance in Medicine, 2010
- Measuring perfusion and permeability in renal cell carcinoma with dynamic contrast‐enhanced MRI: A pilot studyJournal of Magnetic Resonance Imaging, 2010
- Quantification of renal allograft perfusion using arterial spin labeling MRI: initial resultsEuropean Radiology, 2009
- Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma1Academic Radiology, 2005
- Measurement of renal tumour and normal tissue perfusion using positron emission tomography in a phase II clinical trial of razoxaneBritish Journal of Cancer, 2003
- Absolute renal blood flow quantification by dynamic MRI and Gd-DTPAEuropean Radiology, 2000
- A Prospective Study of Disease Progression in Patients With Atherosclerotic Renal Artery Stenosis*American Journal of Hypertension, 1996
- Single-nephron pressures, flows, and resistances in hypertensive kidneys with nephrosclerosisKidney International, 1977