Abstract
Airborne pollutants are a leading cause of illness and mortality globally. Electrochemical gas sensors show great promise for personal air quality monitoring to address this worldwide health crisis. However, implementing miniaturized arrays of such sensors demands high performance instrumentation circuits that simultaneously meet challenging power, area, sensitivity, noise and dynamic range goals. This paper presents a new multi-channel CMOS amperometric ADC featuring pixel-level architecture for gas sensor arrays. The circuit combines digital modulation of input currents and an incremental ΣΔ ADC to achieve wide dynamic range and high sensitivity with very high power efficiency and compact size. Fabricated in 0.5 μm CMOS, the circuit was measured to have 164 dB cross-scale dynamic range, 100 fA sensitivity while consuming only 241 μW and 0.157 mm 2 active area per channel. Electrochemical experiments with liquid and gas targets demonstrate the circuit's real-time response to a wide range of analyte concentrations.Keywords
Funding Information
- National Institute for Occupational Safety and Health (NIOSH) (R01OH009644)
- National Institutes of Health (R01ES022302)
This publication has 37 references indexed in Scilit:
- Single ion channel CMOS electrochemical instrument for high throughput recording arrays2015
- Power efficient instrumentation with 100 fA-sensitivity and 164 dB-dynamic range for wearable chronoamperometric gas sensor arrays2015
- Chopper-Stabilized Bidirectional Current Acquisition Circuits for Electrochemical Amperometric BiosensorsIEEE Transactions on Circuits and Systems I: Regular Papers, 2013
- Compact Low-Power Impedance-to-Digital Converter for Sensor Array MicrosystemsIEEE Journal of Solid-State Circuits, 2009
- VLSI Potentiostat Array With Oversampling Gain Modulation for Wide-Range Neurotransmitter SensingIEEE Transactions on Biomedical Circuits and Systems, 2007
- A Multichannel Femtoampere-Sensitivity Potentiostat Array for Biosensing ApplicationsIEEE Transactions on Circuits and Systems I: Regular Papers, 2006
- Theory and Applications of Incremental$Delta Sigma $ConvertersIEEE Transactions on Circuits and Systems I: Regular Papers, 2004
- On the design and characterization of femtoampere current-mode circuitsIEEE Journal of Solid-State Circuits, 2003
- A Nyquist-rate pixel-level ADC for CMOS image sensorsIEEE Journal of Solid-State Circuits, 1999
- An inherently linear and compact MOST-only current division techniqueIEEE Journal of Solid-State Circuits, 1992