Analysis of Non Detection Zone for multiple distributed PCS based on Equivalent Single PCS using reactive power approach
Authors:
- 1 March 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1220-1226
Abstract
In this paper, the methodology to analyze Non-Detection Zone (NDZ) of islanding detection algorithm for multiple Power Conditioning Systems (PCSs) connected to grid is proposed. The PCSs with renewable energy source or battery energy storage system are equipped with anti-islanding functionality and the method using frequency positive-feedback is one of the most popular methods to detect islanding condition. Because it is figured out that the positive feedback of grid frequency is only valid on reactive current, not the phase of current or active current, the reactive power according to the frequency drift algorithm is only considered for NDZ analysis in the proposed analysis. Additionally, the reactive power component by frequency drift anti-islanding can be linearized in normal operation range of grid frequency. By incorporated with this concept, Equivalent Single PCS (ESPCS), which equivalently supplies whole reactive current of multiple PCSs, is proposed and this could emulate the operation of multiple parallel PCSs without loss of the detection capability. The NDZ is analyzed by ESPCS and is compared to the NDZ of parallel PCSs. Through the computer simulation and hardware experiments, it is confirmed that NDZ based on ESPCS and operation dynamics is well matched to those of multiple PCSs.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Non-Detection Zone of frequency drift anti-islanding with closed-loop power controlled Distributed Generators2015
- A bilateral reactive power injection method for islanding detection of grid-connected converters in distributed generation units2015
- Anti-islanding accelerated by grid unbalance component2015
- Phase-Locked Loop Based on an Observer for Grid SynchronizationIEEE Transactions on Industry Applications, 2013
- Dynamic Non-Detection Zones of Positive Feedback Anti-Islanding Methods for Inverter-Based Distributed GeneratorsIEEE Transactions on Power Delivery, 2011
- Anti-islanding protection for distributed generation systems based on reactive power drift2009
- A $Q$– $f$ Droop Curve for Facilitating Islanding Detection of Inverter-Based Distributed GenerationIEEE Transactions on Power Electronics, 2009
- Islanding Detection Assessment of Multi-Inverter Systems With Active Frequency Drifting MethodsIEEE Transactions on Power Delivery, 2007
- Performance Assessment of Active Frequency Drifting Islanding Detection MethodsIEEE Transactions on Energy Conversion, 2006