Background Respiratory variations in pulse pressure (ΔPP) predict fluid responsiveness during mechanical ventilation. Variations in pulse oximetry plethysmography amplitude (ΔPOP) are proposed as a non-invasive alternative. Large variations in ΔPOP and poor agreement between ΔPP and ΔPOP are found in intensive care unit patients. General anaesthesia is suggested to reduce variability of ΔPOP and improve agreement between the variables. We evaluated the variability of the agreement between and the diagnostic values of ΔPP and ΔPOP during ongoing open abdominal surgery. The variability of diagnostic methods in specific clinical conditions is important, as this reflects the stability over time during which clinical decisions are made. Methods Observational study during open abdominal surgery in general anaesthesia. ΔPP and ΔPOP were calculated semi-automatically from recording periods of approximately 5 min both before and after fluid challenges. Fluid responsiveness was evaluated by changes in stroke volume (oesophageal Doppler) after 250 ml colloid. Results Thirty-four fluid challenges were performed in 25 patients. Variance both within registration periods and between patients were significantly larger for ΔPOP than for ΔPP (54.1% vs. 22.1% and 69.6% vs. 22.6%, respectively, both P < 0.001). Limits of agreement with a regression-based correction were ± 13.9%. Areas under receiver operating characteristics curves for fluid responsiveness were 0.67 for ΔPP and 0.72 for ΔPOP. Conclusions Analysis of raw signals during open abdominal surgery documents that the variance of ΔPOP is larger than of ΔPP, with wide limits of agreement between ΔPP and ΔPOP. The diagnostic values of ΔPP and ΔPOP are relatively poor.Keywords
This publication has 32 references indexed in Scilit:
- Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion indexActa Anaesthesiologica Scandinavica, 2011
- Assessing fluid responsiveness in critically ill patients: False-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle*Critical Care Medicine, 2009
- Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*Critical Care Medicine, 2009
- Photoplethysmography and nociceptionActa Anaesthesiologica Scandinavica, 2009
- Oscillations in the Plethysmographic Waveform Amplitude: Phenomenon Hides Behind ArtifactsAnesthesiology, 2009
- Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated PatientsAnesthesiology, 2009
- Poor Agreement between Respiratory Variations in Pulse Oximetry Photoplethysmographic Waveform Amplitude and Pulse Pressure in Intensive Care Unit PatientsAnesthesiology, 2008
- Ventilation-Induced Plethysmographic Variations Predict Fluid Responsiveness in Ventilated Postoperative Cardiac Surgery PatientsAnesthesia & Analgesia, 2007
- Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia2007
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986