Noninvasive Monitoring of Intracranial Pulse Waves
- 28 June 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 144-153
Abstract
Objective: The clinical management of several neurological disorders benefits from the assessment of intracranial pressure and craniospinal compliance. However, the associated procedures are invasive in nature. Here, we aimed to assess whether naturally occurring periodic changes in the dielectric properties of the head could serve as the basis for deriving surrogates of craniospinal compliance noninvasively. Methods: We designed a device and electrodes for noninvasive measurement of periodic changes of the dielectric properties of the human head. We characterized the properties of the device-electrode-head system by measurements on healthy volunteers, by computational modeling, and by electromechanical modeling. We then performed hyperventilation testing to assess whether the measured signal is of intracranial origin. Results: Signals obtained with the device on volunteers showed characteristic cardiac and respiratory modulations. Signal oscillations can be attributed primarily to changes in resistive properties of the head during cardiac and respiratory cycles. Reduction of end-tidal CO 2 , through hyperventilation, resulted in a decrease in the signal amplitude associated with cardiovascular action. Conclusion: Given the higher CO 2 reactivity of intracranial vessels compared to extracranial ones, the results of hyperventilation testing suggest that the acquired signal is, in part, of intracranial origin. Significance: If confirmed in larger cohorts, our observations suggest that noninvasive capacitive acquisition of changes in the dielectric properties of the head could be used to derive surrogates of craniospinal compliance.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (182683)
This publication has 38 references indexed in Scilit:
- Model-Based Noninvasive Estimation of Intracranial Pressure from Cerebral Blood Flow Velocity and Arterial PressureScience Translational Medicine, 2012
- Implementation of a new CSF dynamic device: a multicenter feasibility study in 562 patientsActa Neurologica Scandinavica, 2011
- Effect of Hyper- and Hypocapnia on Cerebral Arterial Compliance in Normal SubjectsJournal of Neuroimaging, 2011
- Regional Cerebral Blood Flow Using Quantitative MR AngiographyAmerican Journal of Neuroradiology, 2007
- Clinical comparison of tympanic membrane displacement with invasive intracranial pressure measurementsPhysiological Measurement, 2005
- Adaptive Noninvasive Assessment of Intracranial Pressure and Cerebral AutoregulationStroke, 2003
- Noninvasive intracranial compliance monitoringJournal of Neurosurgery, 2003
- Tissue resonance analysis: a novel method for noninvasive monitoring of intracranial pressureJournal of Neurosurgery, 2002
- Laboratory testing of the Spiegelberg brain pressure monitor: a technical report CommentaryJournal of Neurology, Neurosurgery & Psychiatry, 1997
- Mean intracranial pressure monitoring by a non-invasive audiological technique: a pilot study.Journal of Neurology, Neurosurgery & Psychiatry, 1989