Seismic reliability‐based ductility demand evaluation for inelastic base‐isolated structures with friction pendulum devices
Authors:
- 19 December 2016
- journal article
- research article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 46 (8) , 1245-1266
Abstract
Summary: The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
This publication has 37 references indexed in Scilit:
- Seismic structural and non-structural performance evaluation of highly damped self-centering and conventional systemsEngineering Structures, 2011
- Correlation control in small-sample Monte Carlo type simulations I: A simulated annealing approachProbabilistic Engineering Mechanics, 2009
- Non‐linear seismic analysis and vulnerability evaluation of a masonry building by means of the SAP2000 V.10 codeEarthquake Engineering & Structural Dynamics, 2007
- Stochastic Seismic Response and Reliability Analysis of Base-Isolated StructuresJournal of Earthquake Engineering, 2007
- Reliability of base isolation for the protection of critical equipment from earthquake hazardsEngineering Structures, 2005
- Probability-based seismic response analysisEngineering Structures, 2005
- Physical model for dynamic analysis of structures with FPS isolatorsEarthquake Engineering & Structural Dynamics, 2003
- Probabilistic seismic demand analysis of controlled steel moment‐resisting frame structuresEarthquake Engineering & Structural Dynamics, 2002
- Incremental dynamic analysisEarthquake Engineering & Structural Dynamics, 2001
- Performance‐based seismic engineering: the need for a reliable conceptual comprehensive approachEarthquake Engineering & Structural Dynamics, 2001