A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography
- 9 May 2022
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (22) , 2179-2187
Abstract
Background: plasma soluble growth stimulating gene protein 2 (sST2) is a new generation biomarker in heart failure (HF), which is an independent predictor of adverse outcomes of heart failure. Thus, the establishment of a rapid and sensitive method for detecting sST2 is urgently needed. Methods: lanthanide element Eu3+ coated fluorescent nanometer microspheres (Eu3+@FMN) can be used as markers to label monoclonal mouse anti-human sST2 antibody ST-01 (ST-01-Eu3+@FMN). When the immune sandwich complex formed between the monoclonal mouse anti-human sST2 antibody ST-02 and ST-01-Eu3+@FMN on the test band with the appearance of target object sST2, we can detect the fluorescence intensity of Eu3+ on the test band and the quality control band using a dry fluorescence analyzer. We calculated the T/C value (T/C = fluorescence intensity of the test band/fluorescence intensity of the quality control band), fitted to the calibration curve, and measured the concentration value of sST2 in the corresponding sample. Results: the best reaction time was 15 min after condition exploration, and the optimal sample volume was 80 μL. The detection sensitivity of the scheme was 2.14 ng mL−1. The calibration curve of the assay was y = 0.0113x + 0.0033, and the linear range was 5–200 ng mL−1. No cross reaction was found when the samples contained BNP, NT-proBNP, and galectin-3, indicating a good specificity. The precision was good with a relative deviation < 15%. The coefficient of variation of detection results of low-concentration samples and high-concentration samples was 4.20% and 3.30% respectively in the same batch of strip tests, so the intra-assay CV was set as 3+@FMN based time-resolved fluorescence immunochromatography analysis and sST2 ELISA kit was 0.98. To confirm the usage of our proposed TRF-ICA for clinical samples, it was used to determine the concentration of sST2 in samples obtained from 34 patients with heart insufficiency, acute and chronic heart failure. As a result, we successfully detected a minimal concentration of 5.21 ng mL−1 and a maximum concentration of 184.26 ng mL−1 for sST2. Conclusion: this technique provides a rapid, simple and quantitative detection method for sST2 in clinics. It can help clinicians to predict the incidence of adverse events in patients with HF.Keywords
Funding Information
- National Natural Science Foundation of China (81802108)
This publication has 18 references indexed in Scilit:
- ST2 and Prognosis in Acutely Decompensated Heart Failure: The International ST2 Consensus PanelThe American Journal of Cardiology, 2015
- The war against heart failure: the Lancet lectureThe Lancet, 2015
- Head-to-Head Comparison of 2 Myocardial Fibrosis Biomarkers for Long-Term Heart Failure Risk StratificationJACC, 2014
- Soluble ST2 Serum Concentration and Renal Function in Heart FailureJournal of Cardiac Failure, 2013
- Rehospitalization for Heart FailureCirculation, 2012
- Soluble ST2 is Associated with Adverse Outcome in Patients with Heart Failure of Ischaemic AetiologyEuropean Journal of Heart Failure, 2012
- The survival of patients with heart failure with preserved or reduced left ventricular ejection fraction: an individual patient data meta-analysisEuropean Heart Journal, 2011
- Midregion Prohormone Adrenomedullin and Prognosis in Patients Presenting With Acute DyspneaJACC, 2011
- Serial Measurement of Growth-Differentiation Factor-15 in Heart FailureCirculation, 2010
- Serial Sampling of ST2 Predicts 90-Day Mortality Following Destabilized Heart FailureJournal of Cardiac Failure, 2008