Measuring contrast sensitivity with inappropriate optical correction*
- 1 November 2000
- journal article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 20 (6) , 442-451
Abstract
Summary: Spatial frequency‐selective minima (notches) in the contrast sensitivity function (CSF) because of defocus can mimic those that occur with ocular disease. We examined the influence of measurement conditions on CSF shape in simulated clinical testing. CSF notches occurred with almost all levels of defocus for all subjects. Multiple notches were found under some conditions. Notches were found with defocus as small as 0.50 D. Effects of induced astigmatism depended on the orientation of the target. Notches were apparent in defocus conditions after stimulus size and room illuminance were modified and when subjects had insufficient accommodation to compensate for hypermetropic defocus. The equivalent of notches was not noted with the Pelli‐Robson chart. As defocus‐induced CSF notches may be mistaken for functional loss, careful refractive correction should be conducted prior to clinical or experimental CSF measurement, even at low spatial frequencies.Keywords
This publication has 31 references indexed in Scilit:
- Effects of defocus and pupil size on human contrast sensitivityOphthalmic and Physiological Optics, 1999
- Screening for ophthalmic disease in older subjects using visual acuity and contrast sensitivity11The authors have no financial interest in any of the tests used in this study.Ophthalmology, 1998
- Spatial frequency dependent observer bias in the measurement of contrast sensitivityOphthalmic and Physiological Optics, 1996
- Spatial frequency dependent observer bias in the measurement of contrast sensitivityOphthalmic and Physiological Optics, 1996
- Segmented refraction of the crystalline lens as a prerequisite for the occurrence of monocular polyplopia, increased depth of focus, and contrast sensitivity function notchesJournal of the Optical Society of America A, 1994
- Clinical evaluation of a range of autorefractorsOphthalmic and Physiological Optics, 1993
- A comparison of clinical acuity and contrast sensitivity charts: effect of uncorrected myopiaOphthalmic and Physiological Optics, 1991
- Fluctuations in accommodation: a reviewOphthalmic and Physiological Optics, 1988
- A QUANTITATIVE INVESTIGATION INTO THE EFFECTS OF PUPIL DIAMETER AND DEFOCUS ON CONTRAST SENSITIVITY FOR AN EXTENDED RANGE OF SPATIAL FREQUENCIES IN NATURAL AND HOMATROPINIZED EYESOphthalmic and Physiological Optics, 1987
- Contrast attenuation characteristics of iris clipped intraocular lens implants in situ.British Journal of Ophthalmology, 1985