Abstract
Electrolytes play a pivotal role in regulating cardiovascular functions, hydration, and muscle activation. The current standards for monitoring electrolytes involve periodic sampling of blood and measurements using laboratory techniques, which are often uncomfortable/inconvenient to the subjects and add considerable expense to the management of their underlying disease conditions. The wide range of electrolytes in skin interstitial fluids (ISFs) and their correlations with those in plasma create exciting opportunities for applications such as electrolyte and circadian metabolism monitoring. However, it has been challenging to monitor these electrolytes in the skin ISFs. In this study, we report a minimally invasive microneedle-based potentiometric sensing system for multiplexed and continuous monitoring of Na+ and K+ in the skin ISFs. The potentiometric sensing system consists of a miniaturized stainless-steel hollow microneedle to prevent sensor delamination and a set of modified microneedle electrodes for multiplex monitoring. We demonstrate the measurement of Na+ and K+ in artificial ISFs with a fast response time, excellent reversibility and repeatability, adequate selectivity, and negligible potential interferences upon the addition of a physiologically relevant concentration of metabolites, dietary biomarkers, and nutrients. In addition, the sensor maintains the sensitivity after multiple insertions into the chicken skin model. Furthermore, the measurements in artificial ISFs using calibrated sensors confirm the accurate measurements of physiological electrolytes in artificial ISFs. Finally, the skin-mimicking phantom gel and chicken skin model experiments demonstrate the sensor’s potential for minimally invasive monitoring of electrolytes in skin ISFs. The developed sensor platform can be adapted for a wide range of other applications, including real-time monitoring of nutrients, metabolites, and proteins.Keywords
Funding Information
- Division of Electrical, Communications and Cyber Systems (ECCS-2037405)
- University of Connecticut
- Division of Chemical, Bioengineering, Environmental and Transport Systems (CBET-2103025)
This publication has 60 references indexed in Scilit:
- Acid-Base and Potassium HomeostasisSeminars in Nephrology, 2013
- Acute renal failure, severe sodium and potassium imbalance and sudden tetraplegiaClinical Kidney Journal, 2010
- Potentiometric Ion SensorsChemical Reviews, 2008
- Suction blister fluid as potential body fluid for biomarker proteinsProteomics, 2007
- Fluids and hydration in prolonged endurance performanceNutrition, 2004
- Clinical relevance and management of the major electrolyte abnormalities in congestive heart failure: Hyponatremia, hypokalemia, and hypomagnesemiaAmerican Heart Journal, 1994
- Predictors of Clinical HypomagnesemiaArchives of internal medicine (1960), 1984
- The Salivary Sodium/Potassium Ratio in Hypertension: Relation to Race and Plasma Renin ActivityClinical and Experimental Hypertension. Part A: Theory and Practice, 1982
- Salivary Sodium-Potassium Ratio and Plasma Renin Activity in HypertensionCirculation, 1969
- Suction Blister Device for Separation of Viable Epidermis from Dermis*Journal of Investigative Dermatology, 1968