The High Hip Center
Authors:
- Kevin J BozicKBKevin J Bozic
- Andrew A FreibergAFAndrew A Freiberg
- William H HarrisWHWilliam H Harris
- 1 March 2004
- journal article
- review article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 420 (420) , 101-105
Abstract
Revision of a failed acetabular component presents many challenges to the arthroplasty surgeon. The goal in most cases should be to reconstruct the acetabulum by positioning the hip center as close as possible to the anatomic hip center. However, severe acetabular bone stock deficiency and distorted acetabular anatomy often preclude placement of the acetabular component at the true anatomic hip center. In these cases, many options exist for reconstruction of the acetabulum, including placement of the cup superiorly at a high hip center. Although biomechanical studies have shown that superolateral placement of the hip center may lead to increased moments and forces across the hip (leading to potentially higher rates of loosening), superior only displacement of the hip center does not seem to adversely affect the forces about the hip. Proximal placement of the hip center facilitates contact between intact, viable host bone and the acetabular implant, thereby reducing the need for structural bone grafts, and increasing the chances for stable bony ingrowth. With proper patient selection and meticulous surgical technique, the high hip center can be a useful technique for reconstruction of the deficient acetabulum in the patient with a loose acetabular component after total hip arthroplasty.Keywords
This publication has 26 references indexed in Scilit:
- Jumbo Femoral Head for the Treatment of Recurrent Dislocation Following Total Hip ReplacementJournal of Bone and Joint Surgery, 2002
- Bridging Massive Acetabular Defects With the Triflange CupClinical Orthopaedics and Related Research, 2001
- The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devicesThe Journal of Arthroplasty, 2000
- Acetabular revision arthroplasty using so-called jumbo cementless componentsThe Journal of Arthroplasty, 2000
- JUMBO CUPS AND MORSELIZED GRAFTOrthopedic Clinics of North America, 1998
- Influence of a high hip center on abductor muscle functionArchives of orthopaedic and trauma surgery, 1997
- Effect of superior and superolateral relocations of the hip center on hip joint forcesThe Journal of Arthroplasty, 1996
- How Superior Placement of the Joint Center in Hip Arthroplasty Affects the Abductor MusclesClinical Orthopaedics and Related Research, 1996
- High hip center in revision arthroplastyThe Journal of Arthroplasty, 1994
- High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 yearsThe Journal of Arthroplasty, 1993