Finite element-based feasibility study on utilizing heat flux sensors for early detection of vascular graft infections
Open Access
- 27 September 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-13
Abstract
Aortic vascular graft infections have high morbidity and mortality rate, however, patients often do not show symptoms. Continuous implant surface monitoring will allow for early detection of infections on implant surfaces, which allows for antibiotic treatment prior to biofilm formation. We explore the possibility of using heat flux sensors mounted on an aortic vascular graft to sense the localized heat production at the onset of infectious growth. We apply Finite Element Model simulations to demonstrate changes of the heat transfer coefficient depending on different pulsatile flow parameters. We determine various differences, the main influence being the distance travelled from the inlet of the simulation with the highest heat transfer coefficient closest to the inlet and decreasing along the direction of travel of the fluid. The determined range of heat transfer coefficients of 200 to 4800 W/m2 was applied to a second simulation of the thermal environment of the implant. We determined the heat transfer efficiency of the aortic graft system depending on different graft materials and thicknesses. We are further able to determine that the early detection of infection is possible by comparing the simulated amount of heat flux produced locally with the resolution of a commercial heat flux sensor.Keywords
This publication has 49 references indexed in Scilit:
- A Clinical Investigation into the Relationship between Increased Periwound Skin Temperature and Local Wound Infection in Patients with Chronic Leg UlcersAdvances in Skin & Wound Care, 2010
- C-Reactive Protein, Erythrocyte Sedimentation Rate and Orthopedic Implant InfectionPLOS ONE, 2010
- Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body ResponseThe AAPS Journal, 2010
- Calorimetry of microbial growth using a thermopile based microreactorThermochimica Acta, 2005
- Estimation of the biofilm formation of Escherichia coli K-12 by the cell numberJournal of Bioscience and Bioengineering, 2005
- An analytical study of pulsating laminar heat convection in a circular tube with constant heat fluxInternational Journal of Heat and Mass Transfer, 2004
- Theoretical analysis of heat transfer in laminar pulsating flowInternational Journal of Heat and Mass Transfer, 2002
- Heat transfer in the thermally developing region of a pulsating channel flowInternational Journal of Heat and Mass Transfer, 1993
- Measurement of Instantaneous Blood Flow Velocity and Pressure in Conscious Man with a Catheter-Tip Velocity ProbeCirculation, 1969
- Aortic Length: Angiocardiographic MeasurementsCirculation, 1950