Treatment planning for Flash radiotherapy: General aspects and applications to proton beams
Authors:
- 14 March 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 49 (4) , 2861-2874
Abstract
The increased radioresistence of healthy tissues when irradiated at very high dose rates (known as the Flash effect) is a radiobiological mechanism that is currently investigated to increase the therapeutic ratio of radiotherapy treatments. To maximize the benefits of the clinical application of Flash, a patient‐specific balance between different properties of the dose distribution should be found, that is, Flash needs to be one of the variables considered in treatment planning. We investigated the Flash potential of three proton therapy planning and beam delivery techniques, each on a different anatomical region. Based on a set of beam delivery parameters, on hypotheses on the dose and dose rate thresholds needed for the Flash effect to occur, and on two definitions of Flash dose rate, we generated exemplary illustrations of the capabilities of current proton therapy equipment to generate Flash dose distributions. All techniques investigated could both produce dose distributions comparable with a conventional proton plan and reach the Flash regime, to an extent that was strongly dependent on the dose per fraction and the Flash dose threshold. The beam current, Flash dose rate threshold, and dose rate definition typically had a more moderate effect on the amount of Flash dose in normal tissue. A systematic estimation of the impact of Flash on different patient anatomies and treatment protocols is possible only if Flash‐specific treatment planning features become readily available. Planning evaluation tools such as a voxel‐based dose delivery time structure, and the inclusion in the optimization cost function of parameters directly associated with Flash (e.g., beam current, spot delivery sequence, and scanning speed), are needed to generate treatment plans that are taking full advantage of the potential benefits of the Flash effect.Keywords
Funding Information
- Varian Medical Systems
This publication has 42 references indexed in Scilit:
- 3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluationPhysics in Medicine & Biology, 2017
- Development of the open-source dose calculation and optimization toolkit matRadMedical Physics, 2017
- Assessment of the quality of very high-energy electron radiotherapy planningRadiotherapy and Oncology, 2016
- Single-energy intensity modulated proton therapyPhysics in Medicine & Biology, 2015
- Treatment planning for radiotherapy with very high‐energy electron beams and comparison of VHEE and VMAT plansMedical Physics, 2015
- Feasibility of Proton Transmission-Beam Stereotactic Ablative Radiotherapy versus Photon Stereotactic Ablative Radiotherapy for Lung Tumors: A Dosimetric and Feasibility StudyPLOS ONE, 2014
- Improved efficiency of multi-criteria IMPT treatment planning using iterative resampling of randomly placed pencil beamsPhysics in Medicine & Biology, 2013
- Accelerators for hadrontherapy: From Lawrence cyclotrons to linacsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Optimization of conformal electron beam therapy using energy‐ and fluence‐modulated beamsMedical Physics, 1996
- Hypoxia in Mouse Intestine Induced by Electron Irradiation at High Dose-ratesInternational Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine, 1971