Heat production during different ultrasonic and conventional osteotomy preparations for dental implants
Authors:
- 21 March 2011
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 22 (12) , 1361-1365
Abstract
Objectives: The purpose of this study was to evaluate the intraosseous temperature changes during ultrasonic and conventional implant site preparation in vitro with respect to the effect of load and irrigation volume.Material and methods: Implant sites were prepared using two different ultrasonic devices (Piezosurgery, Mectron Medical Technology and VarioSurg, NSK) and one conventional device (Straumann) at loads of 5, 8, 15 and 20 N and with irrigation volumes of 20, 50 and 80 ml/min. During implant site preparation, temperatures were measured in fresh, equally tempered bovine ribs using two thermocouples placed at a distance of 1.5 mm around the drilling site in cortical and cancellous bone. The preparation time was recorded.Results: The heat production and time required for implant site preparation using both ultrasonic devices were significantly higher than those for conventional drilling (PConclusions: Ultrasonic implant site preparation is more time consuming and generates higher bone temperatures than conventional drilling. However, with the levels of irrigation, ultrasonic implant site preparation can be an equally safe method.To cite this article: Rashad A, Kaiser A, Prochnow N, Schmitz I, Hoffmann E, Maurer P. Heat production during different ultrasonic and conventional osteotomy preparations for dental implants. Clin. Oral Impl. Res. xx, 2011; 000–000. doi: 10.1111/j.1600‐0501.2010.02126.xKeywords
This publication has 18 references indexed in Scilit:
- Heat Production by 3 Implant Drill Systems After Repeated Drilling and SterilizationJournal of Oral and Maxillofacial Surgery, 2006
- Effect of implant design on survival and success rates of titanium oral implants: a 10‐year prospective cohort study of the ITI® Dental Implant SystemClinical Oral Implants Research, 2004
- Influence of multiple use of Timedur®-titanium cannon drills: thermal response and scanning electron microscopic findingsClinical Oral Implants Research, 2000
- Effect of drill speed on bone temperatureInternational Journal of Oral and Maxillofacial Surgery, 1996
- LETTERS TO THE EDITORClinical Orthopaedics and Related Research, 1985
- The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamberJournal of Oral and Maxillofacial Surgery, 1984
- Heat caused by drilling cortical bone: Temperature measuredin vivoin patients and animalsActa Orthopaedica, 1984
- Assessment of Bone Viability After Heat Trauma: A Histological, Histochemical and Vital Microscopic Study in the RabbitScandinavian Journal of Plastic and Reconstructive Surgery, 1984
- Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbitThe Journal of Prosthetic Dentistry, 1983
- The healing of surgical defects in alveolar bone produced with ultrasonic instrumentation, chisel, and rotary burOral Surgery, Oral Medicine, Oral Pathology, 1975