Effect of posture and extracranial contamination on results of cerebral oximetry by near-infrared spectroscopy
Authors:
- 2 November 2016
- journal article
- research article
- Published by Springer Nature in Journal of Anesthesia
- Vol. 31 (1) , 103-110
Abstract
Background Near-infrared spectroscopy (NIRS)-based cerebral oximetry is a noninvasive technology used to estimate regional cerebral oxygen saturation (rSO2). Extracranial blood flow is known to substantially affect rSO2 values measured by most clinically available devices. Several studies have also reported that the Trendelenburg position and upright position have a larger effect on rSO2 measurements than the supine position. Therefore, we investigated the effect of these two positions (the Trendelenburg position versus the upright position) and extracranial contamination on rSO2 measurements obtained using two commercially available devices and one prototype device. Methods Twelve healthy volunteers were enrolled in the study. They each had three cerebral oximetry devices applied to their forehead (FORE-SIGHT ELITE™, CAS Medical Systems Inc., Branford, CT, USA; INVOS 5100c™, Medtronic, Minneapolis, MN, USA; and NIRO-TRS, Hamamatsu Photonics, Hamamatsu, Japan). A circumferential pneumatic head cuff was positioned proximal to the NIRS cerebral oximetry sensors. We measured rSO2, heart rate (HR), and blood pressure (BP) in six conditions (supine, Trendelenburg and upright positions, with and without scalp ischemia induced by head cuff inflation) every 5 min with each oximetry device. Total hemoglobin (tHb), which is associated with cerebral blood volume (CBV) as measured by positron emission tomography, was measured using the NIRO-TRS device to determine extracranial blood volume in each position. Results Measurements of rSO2 with all the devices were affected by extracranial contamination. The percentage of extracranial contamination was highest with INVOS 5100c™ in the upright position (INVOS, 21.3%; FORE-SIGHT, 14.3%; NIRO-TRS, 3.6%). Measurements of rSO2 obtained in the upright position were significantly lower than those obtained in the supine position, using INVOS-5100c™ and FORE-SIGHT ELITE™ (71 vs. 74% and 67 vs. 72%, respectively), but not using NIRO-TRS (62 vs. 64%). A significant decrease in tHb was observed after head cuff inflation in the supine and Trendelenburg positions (supine, 0.132–0.123 μmol/l; Trendelenburg, 0.133–0.125 μmol/l). Conclusions Except when using NIRO-TRS, measurements of rSO2 in the forehead are significantly lower when measured in the upright position than in the supine position. All devices in this study were affected by extracranial contamination.Keywords
Funding Information
- Departmental funding
This publication has 27 references indexed in Scilit:
- Influence of Beach Chair Position on Cerebral Oxygen SaturationJournal of Neurosurgical Anesthesiology, 2013
- Clinical Validity of Cerebral Oxygen Saturation Measured by Time-resolved Spectroscopy During Carotid EndarterectomyJournal of Neurosurgical Anesthesiology, 2013
- The effect of pneumoperitoneum in the steep Trendelenburg position on cerebral oxygenationActa Anaesthesiologica Scandinavica, 2009
- The Effect of Gynaecological Laparoscopic Surgery on Cerebral OxygenationJournal of International Medical Research, 2006
- Cerebral hemodynamics evaluation by near-infrared time-resolved spectroscopy: Correlation with simultaneous positron emission tomography measurementsNeuroImage, 2006
- Evaluation of a Near-Infrared Spectrometer (NIRO 300) for the Detection of Intracranial Oxygenation Changes in the Adult HeadStroke, 2001
- Muscle Tensing During StandingStroke, 2001
- Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamicsCritical Care Medicine, 1991
- Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical propertiesApplied Optics, 1989
- Noninvasive, Infrared Monitoring of Cerebral and Myocardial Oxygen Sufficiency and Circulatory ParametersScience, 1977