Adjustment of Serum Total Calcium for Albumin Concentration: Effects of Non-Linearity and of Regression Differences between Laboratories
Authors:
- 1 January 1996
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 33 (1) , 55-58
Abstract
It has been reported that the relationship between serum total calcium and albumin concentrations in hospital patients deviates from linearity at low albumin concentrations. We searched a large laboratory computer data base for adult patients with discretionary requests for serum calcium analysis but with no other data suggestive of disturbances of calcium homeostasis, and collected a minimum of 100 calcium values at each of a wide range of albumin concentrations. We confirmed the earlier observation, but found that the use of a single regression to derive an adjustment of total calcium for albumin gave only small differences of no clinical significance. To investigate whether equations to adjust total calcium for albumin can be transferred between laboratories, three laboratory computers were searched for calcium requests from patients likely to have a low prevalence of calcium disturbances. The regressions of total calcium on albumin differed significantly between laboratories, but within each laboratory gave adjusted calcium values identical with those in health. Although the errors resulting from applying an equation from one laboratory to another were small and unlikely to be of major clinical significance, we recommend that where possible laboratories should derive adjustment equations from their own data.Keywords
This publication has 8 references indexed in Scilit:
- Comparison of hypertonic and isotonic reference electrode junctions for measuring ionized calcium in whole blood: a clinical studyClinical Chemistry, 1993
- Serum Albumin by Dye-Binding: Bromocresol Green or Bromocresol Purple? The Case for ConservatismAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1988
- Protein Interferes with Ionised Calcium Measurement at the Reference Electrode Liquid JunctionAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1987
- The Adjusted Serum Calcium Concept—A ReappraisalAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1986
- The Measurement of Albumin in Serum and PlasmaAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1985
- Interpretation of serum total calcium: effects of adjustment for albumin concentration on frequency of abnormal values and on detection of change in the individual.Journal of Clinical Pathology, 1979
- Interpretation of Serum Calcium in Patients with Abnormal Serum ProteinsBMJ, 1973
- Binding of Calcium to Serum Albumin I. Stoichiometry and Intrinsic Association Constant at Physiological pH, Ionic Strength, and TemperatureScandinavian Journal of Clinical and Laboratory Investigation, 1971