Mitigation of Motion Artifacts in Handheld Laser Speckle Contrast Imaging Illustrated on Psoriasis Lesions
Open Access
- 5 August 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (1) , 70-78
Abstract
Background : Handheld laser speckle contrast imaging (LSCI) is crucial in clinical settings, but motion artifacts (MA) can compromise perfusion image reliability. Current prevention and suppression methods are often impractical or complex. Machine vision techniques, promising in medical imaging, could improve signal quality, but their use in suppressing MA is still unexplored. Objective : We propose an innovative method based on linear regression for MA correction (MAC) in LSCI and validate it in vivo. Methods : We performed paired handheld and mounted LSCI measurements on 14 subjects with psoriasis using the previously validated handheld perfusion imager (HAPI). By marking lesion boundaries for clinical purposes, the HAPI used a monochromatic camera for both speckle imaging and motion detection, simplifying hardware requirements. Accurate estimation of relative displacements between the test object and LSCI probe allowed us to apply MAC to the perfusion images. Results : Local perfusion values correlated with applied speed were used to calculate and correct MA. The difference between mean perfusion in handheld and mounted modes after MAC significantly decreased (median error 14.2 perfusion units (p.u.) on lesions before correction ( $p< 0.0005$ ) and 0.5 p.u. after correction ( $p=0.2$ )). Conclusion : The findings provide evidence for robust handheld LSCI and validate the MA technique in psoriasis case. Of the two causes of MA-onsurface speeds and wavefront tilt-we address the former and correct mean perfusion, assuming constant temporal perfusion at each location. Significance : We describe a practical, non-contact, marker-free technique for reliable handheld perfusion imaging, supporting further clinical translation in plastic surgery and burns.Keywords
Funding Information
- Netherlands Organization for Scientific Research
- Domain Applied and Engineering Sciences (14538)
This publication has 34 references indexed in Scilit:
- Correcting non-rigid intra-frame motion of laser speckle contrast imaging by heterogeneous regression analysisOptics and Lasers in Engineering, 2023
- Characterization of motion dependent magnetic field inhomogeneity for DWI in the kidneysMagnetic Resonance Imaging, 2023
- Utility and usability of laser speckle contrast imaging (LSCI) for displaying real-time tissue perfusion/blood flow in robot-assisted surgery (RAS): comparison to indocyanine green (ICG) and use in laparoscopic surgerySurgical Endoscopy, 2022
- A robust quantitative approach for laser speckle contrast imaging perfusion analysis revealed anomalies in the brain blood flow in offspring mice of preeclampsiaMicrovascular Research, 2022
- Movement correction method for laser speckle contrast imaging of cerebral blood flow in cranial windows in rodentsJournal of Biophotonics, 2021
- Motion correction of laser speckle imaging of blood flow by simultaneous imaging of tissue structure and non-rigid registrationOptics and Lasers in Engineering, 2021
- Application of optical flow algorithms to laser speckle imagingMicrovascular Research, 2019
- Optimisation of movement detection and artifact removal during laser speckle contrast imagingMicrovascular Research, 2015
- Laser speckle contrast imaging accurately measures blood flow over moving skin surfacesMicrovascular Research, 2011
- Flow visualization by means of single-exposure speckle photographyOptics Communications, 1981