Surgically Induced Astigmatism after Cataract Surgery – A Vector Analysis
- 25 July 2022
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 47 (9) , 1279-1287
Abstract
Background: Surgically induced astigmatism (SIA) has been widely discussed in the literature as the change in corneal astigmatism resulting from corneal incision. The purpose of this study was to investigate the change in corneal refractive power preoperative to postoperative using a vector analysis of keratometry, total keratometry, and corneal back surface data from a modern optical biometer Methods: The analysis was based on a dataset of 122 eyes of 122 patients with preoperative and 1 month postoperative measurements performed with the IOLMaster 700 biometer from 1 clinical centre and a standardised surgical technique involving a corneal 2.5 mm 45°-incision made from the superior direction. Keratometry, total keratometry and corneal back surface data were processed in 3 vector components (spherical equivalent power SEQ and astigmatism considered in 0°/90° (C0°) and in 45°/135° (C45°) meridian), and the changes in corneal power vectors were analysed, comparing preoperative to postoperative values. Results: The mean corneal power of total keratometry reduced slightly after cataract surgery (-0.05 dpt), resulting mostly from a decrease in back surface power (-0.04 dpt). The astigmatism vector component C0° of total keratometry reduced by -0.28 dpt, mostly due to a decrease at the corneal front surface (-0.26 dpt). With the corneal incision at 12 o’clock position this flattening in the 90° meridian refers to a SIA of around ¼ dpt. The change in C0° and the C45° astigmatic vector components for both keratometry and total keratometry show a large variation ranging between 0.24 and 0.33 dpt (standard deviations), indicating a poor predictability of the change in astigmatism due to cataract surgery. Conclusion: Cataract surgery locally flattens the cornea in the incision meridian. This flattening shows a large individual variation and therefore a poor predictability. Our study indicates that SIA in modern cataract surgery with standardised corneal incision is in a range of 1/4 dpt.Keywords
This publication has 23 references indexed in Scilit:
- Effect of Limbal Relaxing Incisions on Corneal AberrationsJournal of Refractive Surgery, 2016
- Analysis of Surgically Induced Astigmatism on the Posterior Surface of the CorneaJournal of Refractive Surgery, 2014
- Effects of steep meridian incision on corneal astigmatism in phacoemulsification cataract surgeryJournal of Cataract & Refractive Surgery, 2012
- Effect on Astigmatism of the Location of Clear Corneal Incision in Phacoemulsification of CataractJournal of Refractive Surgery, 2007
- Corneal astigmatism correction with opposite clear corneal incisions or single clear corneal incision: Comparative analysisJournal of Cataract & Refractive Surgery, 2006
- Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatismJournal of Cataract & Refractive Surgery, 2006
- Paired opposite clear corneal incisions to correct preexisting astigmatism in cataract patientsJournal of Cataract & Refractive Surgery, 2005
- Opposite clear corneal incisions on the steep meridian in phacoemulsificationJournal of Cataract & Refractive Surgery, 2004
- Correlation between polar values and vector analysisJournal of Cataract & Refractive Surgery, 1997
- Evaluating surgically induced astigmatismJournal of Cataract & Refractive Surgery, 1994